My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2014_8
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2014_8
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 12:38:44 PM
Creation date
7/3/2020 10:58:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2014_8
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2014_8.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
595
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
composite liner will exceed typical standards of practice by mandating that dedicated <br />CQA technician be available to monitor gravel and/or operations layer placement on a <br />full time basis. Further, recognizing that the greatest volume of fluids is likely to <br />accumulate in the sumps, electrostatic testing of the FML in all sump areas will be <br />completed in addition to the more conventional CQA testing protocols. <br />On the basis of the approved CQA Plan, an intensive field testing program will be <br />implemented during construction to evaluate whether the composite liner system <br />components are constructed according to the design specifications. All field tests will be <br />conducted by CQA personnel or qualified laboratories under the supervision of the CQA <br />personnel. All field observations and field testing will be recorded on inspection data <br />sheets which in combination with the technician's daily reports will be used to formulate <br />daily summary reports. All field testing will follow ASTM standard test procedures in <br />accordance with the CQA Plan. Daily inspection reports, inspection data sheets, and <br />inspection photographs will be reviewed by the CQA Manager. All inspection reports <br />will be evaluated for internal consistency, accuracy, and completeness. The above daily <br />reports will be summarized into periodic acceptance reports, which will indicate that <br />work has been completed according to the specified design. These reports will be <br />included in the project files and will be available to regulatory agencies upon request. <br />Recognizing the potential for damage to the liner during placement of the LCRS and <br />operations layers, after installation of the liner, LCRS, and operations layer, an <br />electrostatic test will be performed to identify any manufacturer- or construction -related <br />defects in discrete portions of the FML. These tests will be performed by qualified <br />is testing personnel who will report directly to the CQA Manager. As with all CQA reports, <br />the electrostatic test reports will be included in the project files and will be available to <br />regulatory agencies upon request. <br />At the completion of each phase of liner construction, a final report will be prepared to <br />include: <br />• Daily inspection summary reports. <br />• Field and laboratory test result sheets. <br />• Electrostatic FML test result sheets. <br />• Inspection data sheets. <br />• Photographic reporting data sheets. <br />• As -built reports. <br />• Deviations from design and material specifications (with justifying <br />documentation). <br />A statement that the liner has been built in general conformance with the design <br />specifications, the approved plans, and the approved modifications of the plans and <br />specifications will be provided and included in the final documentation sent to the <br />appropriate regulatory agencies. Upon completion of liner construction, the facility will <br />store all original documents so that they are protected from damage, yet can be readily <br />accessed. <br />M <br />Cd2000.04SWorward Composite Liner Y7 .dac\09119/02 <br />Geologic Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.