Laserfiche WebLink
MONITORING AND REPORTING PROGRAM NO. R5-2014-0006 4 <br /> FORWARD INC.AND REPUBLIC SERVICES INC. <br /> FORWARD CLASS II LANDFILL <br /> SAN JOAQUIN COUNTY <br /> 2. Unsaturated Zone Monitoring <br /> The Discharger shall operate and maintain an unsaturated zone detection <br /> monitoring system that complies with the applicable provisions of Title 27, <br /> sections 20415 20420, 20425 and 20430. The current unsaturated zone <br /> detection monitoring system does not meet the applicable requirements of Title <br /> 27. The system is inadequate from general lack of maintenance. WDR Order <br /> R5-2014-0006 includes a time schedule for a status review, general <br /> maintenance and repair/replacement of damaged or missing monitoring points. <br /> In addition, the Discharger shall install unsaturated zone monitoring devices <br /> (after review and approval by Central Valley Water Board staff) each time the <br /> landfill constructs a new cell or module. <br /> The current unsaturated zone monitoring network shall consist of.- <br /> Unit <br /> f:Unit Monitored Type Monitoring Points <br /> F - North Suction E-1, E-2, W-1, W-2 <br /> F - West Suction LY-Pond-N, LY-Pond-S <br /> Background Suction LY-BG-1 <br /> Forward Suction LY-A, LY-EIA, LY-E1B, LY-E2A, LY-E2B, D93A, <br /> D93B, <br /> Austin Road Suction FU-03, FU-04W, FU-04E, FU-05, FU-06 <br /> Forward Pan D-01 S, D-01 N, D-02 <br /> Austin Road Pan FU-03, FU-04W, FU-04E, FU-05, FU-06 <br /> Any new unsaturated zone monitoring point shall be added to the monitoring <br /> network and shall be monitored at the same frequency as existing monitoring <br /> points. Unsaturated zone samples shall be collected from the monitoring <br /> network listed above and shall be analyzed for the parameters and constituents <br /> listed in Table II in accordance with the specified methods and frequencies <br /> (however, pan lysimeters need only be sampled when liquid is present). Pan <br /> lysimeters shall be inspected for the presence of liquid quarterly. If liquid is <br /> detected in a previously dry pan lysimeter, the Discharger shall verbally notify <br /> Central Valley Water Board staff within seven days and shall immediately <br /> sample and test the liquid for Field and Monitoring Parameters listed in Table ll. <br /> Samples collected for the 5-year COC analyses specified in Table II shall be <br /> collected and analyzed in accordance with the methods listed in Table VI every <br /> five years, beginning again in 2018 (does not include soil-pore gas). <br /> The Discharger shall collect, preserve, and transport samples in accordance <br /> with the quality assurance/quality control standards contained in the approved <br /> Sampling and Analysis Plan. <br />