My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2014_8
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2014_8
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 12:38:44 PM
Creation date
7/3/2020 10:58:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2014_8
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2014_8.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
595
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO. R5-2014-0006 15 <br /> FORWARD INC.AND REPUBLIC SERVICES INC. <br /> FORWARD CLASS II LANDFILL <br /> SAN JOAQUIN COUNTY <br /> m) Results of the corrective action monitoring. <br /> n) A description of the measures undertaken to implement the "Forward Landfill <br /> Odor Control Management Plan" (revised September 2007) and the "Odor <br /> Impact Minimization Plan" (dated March 2009). <br /> 2) Annual Monitoring Report: The Discharger shall submit an Annual Monitoring <br /> Report to the Central Valley Water Board by 1 February covering the reporting period of <br /> the previous monitoring year. If desired, the Annual Monitoring Report may be combined <br /> with the fourth quarter report, but if so, shall clearly state that it is both a quarterly and <br /> annual monitoring report in its title. Each Annual Monitoring Report shall contain the <br /> following information: <br /> a) All monitoring parameters, if detected, shall be graphed to show historical <br /> trends at each monitoring point and background monitoring point, for all <br /> samples taken within at least the previous five calendar years. If a 5-year <br /> COC event was performed, the detected parameters shall be graphically <br /> presented if they were also detected during any previous COC event. Each <br /> such graph shall plot the concentration of one or more constituents for the <br /> period of record for a given monitoring point or background monitoring point, at <br /> a scale appropriate to show trends or variations in water quality. The graphs <br /> shall plot each datum, rather than plotting mean values. Graphical analysis of <br /> monitoring data may be used to provide significant evidence of a release. <br /> b) An evaluation of the monitoring parameters with regards to the cation/anion <br /> balance, and a graphical presentation using a Stiff diagram, a Piper graph, or <br /> a Schoeller plot. <br /> c) All historical monitoring data for which there are detectable results, including <br /> data for the previous year, shall be submitted in tabular form in a digital file <br /> format such as a computer disk. The Central Valley Water Board regards the <br /> submittal of data in hard copy and in digital format as "...the form necessary <br /> for..." statistical analysis [Title 27, section 20420(h)], that facilitates periodic <br /> review by the Central Valley Water Board. <br /> d) Hydrographs of each well showing the elevation of groundwater with respect to <br /> the elevations of the top and bottom of the screened interval and the elevation <br /> of the pump intake. Hydrographs of each well shall be prepared quarterly and <br /> submitted annually. <br /> e) A comprehensive discussion of the compliance record, and the result of any <br /> corrective actions taken or planned which may be needed to bring the <br /> Discharger into full compliance with the waste discharge requirements. <br /> f) A map showing the area and elevations in which filling has been completed <br /> during the previous calendar year and a comparison to final closure design <br />
The URL can be used to link to this page
Your browser does not support the video tag.