Laserfiche WebLink
Table 7 <br /> Postclosure Annual Maintenance Cost Estimate <br /> North County Recycling Center and Sanitary Landfill <br /> San Joaquin County,California <br /> Items Quantity Units Unit Cost Subtotals <br /> COVER REPAIR <br /> Soil(I%of landfill area) 9,000 CY $2 $24,000 <br /> Sedding and Mulching(5%) 10 ACRE $2,000 $20,000 <br /> Cover Repair Subtotal <br /> $44,000 <br /> LEACHATE,COLLECTION <br /> Operation,Maintenance,Disposal 1 LS $0 $0 <br /> Leachate Sampling 1 LS $2,500 $2,500 <br /> Leachate Analysis 1 LS $10,000 $10,000 <br /> 12,500 <br /> Collection Systems Subtotal <br /> Leachate Collec $ <br /> LANDFILL GAS MONITORING <br /> Gas Sampling 1 LS $5,200 $5,200 <br /> Gas Analysis 1 LS $27,000 $27,000 <br /> $32,200 <br /> Landfill Gas Monitoring Subtotal <br /> LANDFILL GAS EXTRACTION SYSTEM <br /> Maintenance 1 LS $165,000 $165,000 <br /> Operation,Maintenance,Disposal 1 LS $200,000 $200,000 <br /> Landfill Gas Extraction System Subtotal <br /> $36 5,000 <br /> GROUNDWATER AND SURFACE WATER MONITORING <br /> Groundwater and Surface Water Sampling I LS $8,000 $8,000 <br /> Analysis 1 LS $6,600 $6,600 <br /> Monitoring Well Maintenance 1 LS $1,000 $1,000 <br /> Groundwater and Surface Water Monitoring Subtotal ai <br /> ................. <br /> 15,600 <br /> VADOSE ZONE MONITORING <br /> Vadose zone sampling 1 LS $2,500 $2,500 <br /> Analysis 1 LS $240 $240 <br /> Vadose Zone Monitoring Subtotal $2,740 <br /> OTHER <br /> Inspections and Record Keeping 1 LS $8,000 $8,000 <br /> Reporting 1 LS $30,000 $30,000 <br /> $38,000 <br /> Other Subtotal <br /> ESTIMATED POSTCLOSURE COST $510,040 <br /> CONTINGENCY(20%) $105,000 <br /> TOTAL ESTIMATED ANNUAL COST $612,000 <br /> TOTAL COST OVER 30 YEARS $18,360,000 <br /> cy=cubic yard <br /> LS=lump sum <br /> All costs are in 2004 dollars. <br /> Analytical costs are based on current(2004)quarterly sampling constituents. 5 year COCs are not included <br /> in the costs <br /> LEACHATE COLLECTION-It is anticipated that each module will have a sump. Although,it is <br /> unlikely that leachate will be present and sampled each quarter,it was assumed that there will be leachate in <br /> each sump each quarter. <br /> LANDFILL GAS MONITORING-Assume one technician samples in 2-8 hour days per quarter. <br /> Sampling 16 wells for TO-14 analysis quarterly. <br /> LANDFILL GAS EXTRACTION-Assume maintenance equals 5%of total gas system cost. Assume <br /> operations equal 1 person full time, 1 person part time,oversight,and electricity. <br /> GROUNDWATER AND SURFACE WATER MONITORING-Assume one technician samples 2 days <br /> per event. Assume quarterly sampling for groundwater and bi-annual for surface water. <br /> VADOSE ZONE SAMPLING-Assume 20 vadose zone samples will be collected. Assume it takes one <br /> technician 8 hours to sample each quarter. <br /> INSPECTION AND RECORD KEEPING-Assume 1 day labor per month. <br /> North County RC and SL Public Works/Solid Waste <br /> JTD County of San Joaquin-November 30,2004 <br />