Laserfiche WebLink
21. Exposure to Asbestos and Exposure Limits: <br /> a. No more than . 2 fibers (longer than 5 microns) per cubic <br /> centimeter of air for an 8-hour time-weighted average; <br /> and for an excursion limit of thirty minutes, no more <br /> than an average of 1.0 fiber per cubic centimeter of air. <br /> b. The following engineering controls must be used to keep <br /> asbestos exposure below limits: Isolation, Enclosure, <br /> Exhaust Ventilation, Dust Collection. <br /> C. The following work practices must be followed: <br /> Asbestos waste and debris must be collected in <br /> sealed impermeable bags. <br /> d. Spills must be cleaned up promptly. <br /> e. Materials must be wetted before removal from containers <br /> unless exposure is controlled by ventilation. <br /> f. Asbestos waste and debris must be collected in sealed <br /> impermeable bags. <br /> g. When engineering controls are not feasible, respiratory <br /> protection for workers is required. <br /> h. If the exposure may exceed the limit, asbestos <br /> concentration must be determined (at employee ' s breathing <br /> zone) . <br /> i. Caution signs must be displayed at locations where w <br /> asbestos fiber concentration may exceed the exposure <br /> limit. <br /> j . All material or scrap containing asbestos must bear a <br /> label - CAUTION: CONTAINS ASBESTOS FIBERS. AVOID <br /> CREATING DUST. BREATHING ASBESTOS DUST MAY CAUSE SERIOUS <br /> BODILY HARM. <br /> 22 . Ventilation in enclosed places must be sufficient to prevent <br /> flammable vapor concentration from exceeding 25% of the L.E.L. <br /> 23 . All corrosive liquids containers must be plainly marked with <br /> a warning legend. Employees must use appropriate protective <br /> equipment when handling corrosives. When employees handle <br /> corrosives frequently, a deluge shower and bubble-fountain <br /> must be provided. <br /> 24 . All Flammable/Combustible containers must be plainly marked <br /> with a warning legend. Flammable liquids must be stored and <br /> transported in closed containers. <br /> a. Flammable liquids must not be used: <br /> - To wash floors, structures, or equipment--except <br /> with adequate ventilation. <br /> 3 - <br />