My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
17720
>
4400 - Solid Waste Program
>
PR0440058
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:37 PM
Creation date
7/3/2020 11:02:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010
RECORD_ID
PR0440058
PE
4433
FACILITY_ID
FA0004518
FACILITY_NAME
NORTH COUNTY LANDFILL
STREET_NUMBER
17720
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06512004
CURRENT_STATUS
01
SITE_LOCATION
17720 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440058_17720 E HARNEY_2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
614
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
expansion. Similar calculations for existing leachate collection pipes in Module 3 show <br />that maximum waste above the most critical pipe should be limited to 165 feet; the <br />proposed final grading reflects this height limitation. <br />The calculations for Modules 5 through 11 show that an HDPE with an SDR of 13.5 <br />should be used to achieve adequate factors of safety under the proposed landfill heights. <br />9.1.3 Flow Capacity of Geonets/Geocomposite Drains <br />Geonet drains were used on both the base and sideslopes of existing Modules 1 and 3. A <br />geocomposite drain is used only on the sideslopes of Module 4. A geocomposite drain <br />will also be used on the sideslopes of all future modules. <br />Based on the computed peak flow from the historical pumping rates and the measured <br />transmissivity of the geonet, the calculations for the existing geonet drains in Modules 1 <br />and 3 show adequate flow capacity. Similarly, existing geocomposite drain on the <br />sideslopes of Module 3 shows adequate flow capacity. <br />The design calculations for the geocomposite drain on the sideslopes of the future <br />modules, based on the peak flow estimated from the HELP simulation, shows that <br />geocomposite drain should have a minimum index transmissivity of 1.8 x 10-4 m2/sec at a <br />hydraulic gradient of 0.33 and a normal load of 35,000 psf. <br />9.1.4 Puncture Protection of Geomembranes <br />Since a geonet drain is used as the leachate collection system in Modules 1 and 3, the <br />puncture protection of the geomembrane within these modules is not a concern. <br />Rounded/subrounded gravel was used as the leachate drainage layer in Module 4. The <br />puncture protection calculations based on the actual grain -size of this gravel shows that <br />the existing geomembrane can withstand the additional loading without a geotextile <br />cushion. <br />Similar calculations show that if rounded/subrounded gravel is used as leachate drainage <br />layer in the future modules, a geotextile cushion would not be required. However, if <br />crushed gravel is used, a 16-oz/yd2 non -woven geotextile cushion should be provided for <br />puncture protection of the underlying geomembrane. <br />9.2.1 Liner System Shear Strength Requirements <br />As discussed in Section 4.2.4, a minimum residual shear strength defined by a friction <br />angle of 12 degrees was assumed for the liner system within all the future modules. The <br />end of filling of Module 9 represents the most critical interim slope stability condition. <br />Geotechnical Analyses for NCRCSL Department of Public Works/Solid Waste <br />Shaw Environmental, hic. County of San Joaquin, December 12, 2007 <br />9-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.