My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
17720
>
4400 - Solid Waste Program
>
PR0440058
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:37 PM
Creation date
7/3/2020 11:02:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010
RECORD_ID
PR0440058
PE
4433
FACILITY_ID
FA0004518
FACILITY_NAME
NORTH COUNTY LANDFILL
STREET_NUMBER
17720
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06512004
CURRENT_STATUS
01
SITE_LOCATION
17720 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440058_17720 E HARNEY_2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
614
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
To maximize the fill capacity, the liner system in each module should meet or exceed the <br />assumed residual shear strength defined by a friction angle of 12 degrees. However, <br />slightly lower liner shear strength may be acceptable in some of the modules where the <br />interim slope stability is less critical than in Module 9. The actual shear strength <br />requirement within each module may be determined in the future during the design of the <br />individual modules, based on both interim and global slope stability analyses of each <br />module. <br />The shear strength of the liner system within each of the future modules should be <br />verified using large-scale direct shear testing (ASTM Method D5321), as part of the <br />construction quality assurance program. The maximum waste height within these <br />modules is 255 feet, which corresponds to a maximum normal stress of approximately <br />20,000 psf. Therefore, the shear strength of the liner systems in Modules 5 through 11 <br />should be tested to a maximum normal load of 20,000 psf. The liner shear strength and <br />testing requirements are summarized in Table 3. As noted in this table, the shear strength <br />of the interface between the GCL and textured HDPE geomembrane should be tested <br />with actual materials proposed for construction of the composite liner. A needle -punched <br />GCL with nonwoven geotextile on both sides should be used in the liner construction. <br />If a geotextile cushion is used above the geomembrane, the interface between the textured <br />geomembrane and the geotextile should be tested to make sure that this interface also <br />meets the 12 degree friction angle requirement. <br />The following procedure is recommended while evaluating the measured shear strength <br />test data: <br />+ If the measured large -displacement shear strength values (corresponding to 3 -inch <br />shear displacement) at all four normal loads listed in Table 3 are greater than <br />those specified, the test results are acceptable. <br />+ If the measured large -displacement shear strength values at all four normal loads <br />are less than those specified in Table 3, the test results are not acceptable. <br />+ If the measured shear large -displacement shear strength values at the lower normal <br />stresses (5,000 and 10,000 psf) exceed those specified in Table 4, but the <br />measured shear strength value at the higher normal stresses (15,000 and 20,000 <br />psf) do not meet those specified in Table 3, the slope stability analysis should be <br />re-evaluated to verify if the measured shear strengths meet the design criteria <br />discussed in Section 2.2. <br />9.2.2 Leachate Pipes within the Future Modules <br />Since an SDR 15.5 leachate pipes shows an inadequate factor of safety against wall <br />crushing, an SDR 13.5 HDPE leachate collection pipes should be used within the future <br />modules. <br />Geotechnical Analyses for NCRCSL Department of Public Works/Solid Waste <br />Shaw Environmental, Inc. County of San Joaquin, December 12, 2007 <br />9-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.