My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1988_2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
Archived Reports
>
ARCHIVED REPORTS_1988_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:52:44 PM
Creation date
7/3/2020 11:04:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1988_2
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_1988_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Method 102 Revision 1 <br />3.3 A gas chromatograph equipped with a gas sampling valve <br />and either a sample loop or freeze -out inlet system and <br />a photoionization detector is required. The detector <br />operates at 10.2 eV. <br />5 Procedure <br />5.1 All bags and samplers are prepared for sampling as out- <br />lined in Appendix A, "Procedures for Atmospheric Bag <br />Sampling". <br />5.2 The air sample is analyzed for ben-_�-ene by using either <br />the loop method or the freeze -out method. The freeze - <br />out method is used for lower benzene concentrations of <br />less than 25 ppb. <br />• <br />5.2.1 The procedure for the loop method follows: <br />5.2.1.1 Transfer the air sample from the air sample bag and <br />inject it into the sample loop of the gas chromatograph <br />using a 100 ml, syringe fitted with a Luer-lok to <br />quick -connect adapter. <br />5.2.1.2 The gas sampling valve has a fixed volume sample loop of <br />about 1 mL. <br />3 <br />3.4 <br />A freeze -out system consisting of a U-shaped stainless <br />steel trap filled with stainless steel clippings is <br />used to concentrate the sample. <br />3.5 <br />A stainless steel column (6 ft x 1/8 in) packed with <br />10% N,N-bis(2--cyanoethyl)formamide on 100/120 mesh <br />Chromosorb PAW is used. <br />3.6 <br />For a confirmation of the benzene analysis, an alter- <br />nate column should be used such as a stainless steel <br />GC column packed with 10% tricyanoethoxy propane (TCEP). <br />3.7 <br />An analog recorder and an electronic integrator to <br />quantify peak areas are required. <br />3.8 <br />Ground glass syringes (100 mL capacity) or other suitable <br />devices are needed to transfer air samples from the <br />Tedlar bag to the GC sample inlet. <br />4 <br />Re@gen Vs <br />4.1 <br />The primary standard used in this anal:rsis should be <br />the National Bureau of Standards (NBS) benzene standard <br />reference material. <br />4.2 <br />Helium with a minimum purity of 99.995% should be used. <br />4.3 <br />Commercial liquid nitrogen (b.p.=-196®) is used to cool <br />freeze -out trap. <br />5 Procedure <br />5.1 All bags and samplers are prepared for sampling as out- <br />lined in Appendix A, "Procedures for Atmospheric Bag <br />Sampling". <br />5.2 The air sample is analyzed for ben-_�-ene by using either <br />the loop method or the freeze -out method. The freeze - <br />out method is used for lower benzene concentrations of <br />less than 25 ppb. <br />• <br />5.2.1 The procedure for the loop method follows: <br />5.2.1.1 Transfer the air sample from the air sample bag and <br />inject it into the sample loop of the gas chromatograph <br />using a 100 ml, syringe fitted with a Luer-lok to <br />quick -connect adapter. <br />5.2.1.2 The gas sampling valve has a fixed volume sample loop of <br />about 1 mL. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.