PR0440006
PE
4434
FACILITY_ID
FA0004515
FACILITY_NAME
FRENCH CAMP LANDFILL
STREET_NUMBER
0
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95231
APN
16307035
CURRENT_STATUS
02
SITE_LOCATION
MANTHEY RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440006_0 MANTHEY_1993-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM -5- <br /> CITY OF STOCKTON <br /> FRENCH CAMP LANDFILL <br /> LIMITED CLASS III LANDFILL <br /> SAN JOAQUIN COUNTY <br /> 5 of Chapter 15. The water quality monitoring system and program shall be <br /> sufficient to demonstrate compliance, or lack thereof, with the Water Quality <br /> Protection Standard. Existing water quality monitoring stations and data can be <br /> proposed for incorporation in the revised monitoring system and program. The <br /> proposal shall includes <br /> A. Proposed conceptual design and location of water quality monitoring points <br /> including those at the point of compliance (§2550.7); <br /> B. Proposed monitoring parameters, constituents of concern, and their monitoring <br /> frequencies (§2550.7 and §2550.8) <br /> C. Proposed concentration limits and/or methods for establishing concentration <br /> limits (§2550.4); and, <br /> D. Proposed statistical methods for determining statistically significant <br /> evidence for a release from WMUs. <br /> The Discharger shall also propose a monitoring system and program pursuant to <br /> §2550.10 of Chapter 15 for determining the effectiveness of any corrective <br /> actions. <br /> Ground Water Monitoring <br /> The existing ground water monitoring system consists of "background" monitoring <br /> well MW-5 and downgradient monitoring wells MW-1, MW-2, MW-3, and MW-4. The <br /> Discharger shall continue to monitor these wells for the constituents and <br /> parameters specified below at the specified frequency until the Discharger°s <br /> revised monitoring program is approved by the Board and the monitoring system is <br /> operational. <br /> Parameter/Constituent Units Freguencv <br /> Temperature °C Quarterly <br /> Turbidity N.T.U. Quarterly <br /> Specific Conductance (field) µmhos/cm Quarterl <br /> pH (field) pH units Quarterly <br /> Total Dissolved Solids mg/l Quarterly <br /> Chloride mg/l Quarterly <br /> SulfiTRPHte 3 mg/ l Semi-annually <br /> TPH as �iesel mg/l Semi-annually <br /> Cadmium mg/l Annually <br /> Lead mg/l Annually <br /> Mercury mg/l Annually <br />
The URL can be used to link to this page
Your browser does not support the video tag.