KLEINFELDER <br /> 2 PROGRAM OVERVIEW <br /> 2.1 GENERAL <br /> This CQA plan is to be implemented to control construction for installation of final cover <br /> for the Landfill. The final cover consists of a minimum two-foot thick foundation layer, <br /> one-foot thick low permeability barrier ("clay") layer and a one-foot thick protective <br /> - vegetative layer. This final cover section was included in the Closure Plan to meet <br /> minimum requirements of Chapter 15, Section 2581(a). <br /> The County has decided to use on-site soils from a borrow area for construction of the final <br /> cover as indicated in the closure plan. The SJDPW retained Kleinfelder to test available <br /> on-site soil and develop a soil amendment mix design to attain the properties needed for <br /> barrier layer construction. The mix design is based on using commercial clay soil obtained <br /> from Ione Refractories and is included in this CQA Plan. <br /> I IL The CQA program also involves using qualified SJDPW personnel to the greatest extent <br /> possible for the following: <br /> • construction of the final cover, <br /> Lengineering closure design services, <br /> • CQA testing and certification of the foundation and vegetative layers, <br /> • construction supervision of County forces, <br /> L <br /> grade control survey, and <br /> �` certification of the foundation and vegetative layer construction. <br /> r- <br /> f . <br /> L If SJDPW forces are not available, qualified contractors will be retained to perform the <br /> work. <br /> L <br /> r <br /> -0 <br /> r <br /> CR9-42 Page 5 of 28 <br /> Copyright 1991 Kteinfetder, Inc. <br />