• i <br /> DECONTAMINATION <br /> 9.1 PERSONNEL AND EQUIPMENT REQUIREMENTS <br /> Field personnel will be wearing the appropriate PPE as described in Section 5.2. All <br /> contaminated disposable clothing (e.g. gloves) will be properly bagged and disposed of <br /> accordingly. All personnel will be instructed to wash hands, face, neck, and forearms at the <br /> end of the work shift and to shower at the end of each workday. In addition, eating, drinking, or <br /> smoking is not permitted on-Site. <br /> Entry into contaminated areas will be limited to avoid unnecessary exposure and potential <br /> spread of contaminants. In the event field or sampling equipment is utilized in the contaminated <br /> areas, the equipment will be properly decontaminated as discussed below. <br /> To ensure that no cross contamination between samples will occur, the sampling equipment will <br /> be decontaminated using a triple rinse process between sampling events. In addition, <br /> equipment leaving the Exclusion/Contamination Zone will also be decontaminated prior to <br /> entering the Support/Clean Zone. The equipment will initially be washed using a solution of <br /> phosphate-free detergent in water followed by rinsing with water. Finally, the equipment will be <br /> rinsed with distilled/deionized water. Equipment decontamination procedures will be <br /> conducted in a designated area on plastic sheeting or equivalent protective surface. Clean <br /> equipment being stored for more than a few hours will be covered with plastic sheeting or <br /> placed in clean plastic bags. <br /> 24 <br /> Lam. <br /> P:\707 Cove Contractors\Groundwater\Well Installation Workplans\SHSP\SHSP_FINAL.doc <br />