My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�� PEI/RP1200 17,--- -- - — _— ----- -- -- - --- ----- <br /> hazardous if done improperly. To prevent <br /> 9. AUTOMATIC LINE LEAK unsafe conditions from developing, follow <br /> DETECTORS the safety precautions described in Section 3 <br /> and lockout/tagout procedures. <br /> Automatic line leak detectors (ALLD) are used with <br /> submersible turbine pump (STP) systems to detect cata- <br /> strophic leaks in pressurized product piping systems. ' <br /> Automatic line leak detectors may be either mechanical <br /> or electronic. <br /> ALLDs must be able to detect a leak in a product line that <br /> is equivalent to 3 gph at 10 psig.Therefore,the test appa- <br /> ratus that is utilized to conduct this test must accurately l MLLD <br /> simulate a leak that is equivalent to 3 gph at 10 prig.This <br /> is accomplished by adjusting the size of the orifice in the <br /> test apparatus until the required flow rate is achieved. <br /> The calibration of the test apparatus leak orifice may be <br /> accomplished either with or without the use of a pressure <br /> regulator. The procedure for calibration with a pressure <br /> regulator is described in Section 9.1.6. The procedure <br /> for calibration without the use of a pressure regulator FIGURE 9-1. The MLLD mounted on the submersible <br /> is described in Section 9.2.6. Either procedure may be turbine pump will restrict flow when a leak is detected. <br /> used to accomplish calibration of the test apparatus leak <br /> orifice. <br /> 9.1 Mechanical Line Leak Detectors (MLLDs). <br /> NOTE: In order for a line leak detector to 9.1.1 General. MLLDs are commonly installed <br /> function properly, the STP must properly <br /> cycle on/off. Confirm that the STP properly at the STP and can detect a leak in product piping <br /> cycles on/off as it would during normal between the MLLD and the solenoid valve inside <br /> product dispensers.MLLDs restrict product flow if <br /> fueling operations and visually inspect the <br /> a leak is detected. <br /> STP electrical relay switches (also known as <br /> "contactors")to ensure that the contacts are in Use this test procedure in conjunction with the <br /> good condition. If the contacts show visible MLLD manufacturer's installation and mainte- <br /> signs of excess arcing,damage or wear,notify nance instructions. <br /> the appropriate person to obtain authorization <br /> to replace the defective relays. If the STP 9.1.2 Purpose. This test method is used to <br /> does not properly cycle on/off, the line leak determine if an MLLD can detect a product line <br /> detector may not detect a leak from the pip- leak equivalent to 3 gph at 10 psig. <br /> ing, and fails the test. <br /> _- 9.1.3 Description of Test. A test apparatus is <br /> typically connected to the test port of the shear <br /> NOTE: Piping configurations with multiple valve inside a dispenser to simulate a leak in the <br /> STPs and manifolded lines or those systems product line equivalent to 3 gph at 10 psig. The <br /> having master/satellite fuel dispensers must performance of the line leak detector is observed <br /> be installed properly for automatic line leak to see if it can detect the simulated leak. <br /> detectors to function correctly.Consult manu- <br /> facturer's literature regarding proper installa- 9.1.4 Test Equipment. Test equipment shall <br /> tion and operation. include: <br /> • test apparatus that includes a pressure gauge <br /> NOTE: Testing of ALLDs involves creating with a minimum range of 0-60 psig, a pressure <br /> a simulated leak from the piping system and regulator and an adjustable orifice that can simu- <br /> activating the STP at specific times to pres- late a leak rate equivalent to 3 gph at 10 psig; <br /> surize the system. These activities can be <br /> pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.