My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at LIST Facilities <br /> • stopwatch or other time-measurement device NOTE:: If the piping has master/satellite dis- <br /> capable of measuring a 1-second increment; pensers, the test apparatus must be connected <br /> • graduated cylinder for measuring leak rate; to the farthest satellite dispenser. <br /> • 5-gallon metal gas test can. 6. Reestablish power to the pump.Open the shear <br /> 9.1.5 Preparation. valve and pressurize the line by activating the <br /> pump. Confirm that no leaks are present in the <br /> NOTE::At some locations with master/satellite test apparatus or the connection to the shear <br /> fuel dispensing installations, the satellite may valve test port. <br /> not be protected by the MLLD.At sites with a 7. Dispense product from the dispenser nozzle <br /> master/satellite fueling location,the test should into the test can to remove all air from the line. <br /> be performed at the most distant satellite dis- <br /> penser so the entire piping system is included. 8: Close the dispenser nozzle and allow the line <br /> to fully pressurize.Record this as the full pump <br /> Conduct the test at the dispenser that has the high- pressure. <br /> est elevation in the system.If there is no difference 9. Shut off the pump, close the shear valve and <br /> in elevation between dispensers, conduct the test allow line pressure to decay until it stabilizes. <br /> using the dispenser farthest from the STP. Record this as the check valve holding pressure. <br /> If the line pressure does not stabilize, this may <br /> Remove from service all dispensers connected to prevent the MLLD from operating properly. <br /> the STP being tested.Verify that the STP relays are <br /> operating properly to ensure that the pump cycles 10.Bleed line pressure to zero by opening the <br /> on and off correctly. test apparatus leak orifice and allowing fluid <br /> to drain into a graduated cylinder. Record the <br /> 9.1.6 MLLD Test Procedure. volume of fluid in the graduated cylinder as <br /> the line resiliency.Close the test apparatus leak <br /> NOTE:: This procedure describes calibration orifice, tum pump back on and observe pres- <br /> of the test apparatus leak orifice with the use sure gauge. Pressure should rise quickly and <br /> of a pressure regulator.If you prefer not to use pause for approximately 2 to 5 seconds before <br /> a pressure regulator, refer to the calibration building to full pump pressure.If the line pres- <br /> procedure described in Section 9.2.6. sure reaches full pump pressure without paus- <br /> ing,this indicates that the leak detector did not <br /> 1.Visually inspect the vent tube. Verify that it "trip" (i.e., move to the leak search position). <br /> is connected at both ends to the appropriate If the leak detector did not move to the leak <br /> locations and that the vent tube is not broken, search position,repeat Step 8.If the leak detec- <br /> kinked,twisted or leaking.If the vent tube is not for still does not move to the leak search posi- <br /> properly connected or is broken,kinked,twisted tion,the leak detector fails the test. <br /> or leaking,notify the appropriate person. <br /> 1-1.Observe the line pressure when it pauses and <br /> 2.Visually inspect the submersible pump area for record this as the metering pressure. <br /> leakage while it is operating. <br /> 12.Measure the length of time it takes from <br /> 3.Shut off power to the pump and perform lock- pausing at the metering pressure until full <br /> out/tagout procedures on the circuit breakers. pump pressure is achieved. Record this as the <br /> 4.Bleed line pressure to zero by activating the opening time.If the opening time is greater than <br /> dispenser and opening the nozzle, allowing fuel 5 seconds,this may indicate that air is trapped <br /> to drain into the test can.After all line pressure in the line, the piping has high resiliency or a <br /> has been bled off, hang up the nozzle and close leak smaller than the leak detector is capable of <br /> the shear valve. detecting may exist in the piping. <br /> 5.Connect the test apparatus to the shear valve test NOTE: Pay close attention to the pressure <br /> port at the appropriate dispenser. If there is no gauge while measuring the opening time, as <br /> elevation change, connect the test apparatus at this happens rather quickly. <br /> the farthest dispenser. <br /> pei.org , <br />
The URL can be used to link to this page
Your browser does not support the video tag.