My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEI/RP1 Z00-17 <br /> 12.3 Procedure. <br /> 12. DOCUMENTATION 1.Perform test and/or inspection services. <br /> 12.1 General. Documentation showing the date and 2.Document results. <br /> type of testing done to verify spill, overfill, leak detec- 3.Review and approve results for accuracy. <br /> tion, secondary containment equipment, shear valve and 4.Provide results to customer in accordance with time <br /> emergency stop operation should be available for review frames set by the AHJ. <br /> according to the requirements of the authority having <br /> jurisdiction (AHJ). 5.Store results electronically, and make them easily <br /> available for inspection and backup systems <br /> 12.2 Purpose. Testers and inspectors shall provide accordingly. <br /> adequate documentation of the services that have been <br /> performed on underground storage tank (UST) systems. Sample forms are provided in Appendix C of this <br /> All test results should include a detailed description of document. <br /> the tests and inspections performed to back up the pass/ <br /> fail criteria. This includes but is not limited to: test start <br /> and stop times; vacuum levels; liquid levels; data gath- <br /> ered while conducting tests and inspections; and photos <br /> when applicable. In addition, test and inspection results <br /> shall be made available to the responsible persons for the <br /> UST systems in a timely manner and within time frames <br /> required by the AHJ. Results shall be maintained for <br /> appropriate time frames by the tester/inspector as well as <br /> by the owner/operator.Electronic data can be maintained <br /> indefinitely and should not be discarded. <br /> 0 pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.