My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEI/RP1200-17 <br /> Underground Fiberglass Double and Triple-Wall Repeat steps 4 and 5 until a stable vacuum is <br /> Tanks With Dry Annular Space FTPI 4/01/07. achieved. If a stable vacuum cannot be main- <br /> 4.2.7 Test Equipment. Test equipment shall <br /> tained, the tank secondary containment integ- <br /> include: rity test fails. <br /> 7. When the vacuum level stabilizes, record the <br /> • a vacuum-generating device that can be used in vacuum level and the test start time. <br /> a Class I,Division 1 area capable of pulling 15 <br /> inches of mercury(Hg)vacuum; S. Observe the vacuum level for the period of <br /> time shown in Table 4-1. <br /> • an automatic vacuum shutoff valve or vacuum <br /> regulator (The shutoff valve can be set to 9. Record the final time and vacuum level. <br /> close at a predetermined safe level, preventing 10. Check the interstitial space for accumulation <br /> the possibility of accidentally imposing a high of liquids. <br /> vacuum that could damage the tank.The use of <br /> the valve is recommended because it limits the <br /> vacuum that can be applied to the interstitial710 <br /> Capacity, Duration, <br /> space.); gallons hours <br /> • vacuum gauge with a range of 0 inches to 30 <20.000 1 <br /> inches Hg graduated in increments of 0.5 inches 20,000+ 2 <br /> Hg or less; <br /> 4.2.9 Pass/Fail Criteria. If there is no loss in <br /> • toggle valve and vacuum hose; vacuum level, no liquids are drawn into the inter- <br /> • stopwatch or other time measurement device stitial space during the test duration shown in Table <br /> capable of measuring a l-second increment; 4.1, and the tank secondary containment area has <br /> • plumber's plug. no additional fluid than at the start of the test,then <br /> the tank secondary containment passes the test. <br /> 4.2.8 Test Procedure. <br /> If there is any vacuum lost during the test or liquids <br /> 1. Install the plumber's plug in the interstitial are drawn into the interstitial space, then the tank <br /> riser(s)below any tees. secondary containment fails the test. <br /> 2. Connect the vacuum gauge, valve and the 4.3 Tank Secondary Containment Integrity Testing <br /> vacuum-generating device to the fitting on the _Liquid-Filled Test Method. <br /> plumber's plug. The valve should be between <br /> the vacuum source inlet and the pressure 4.3.1 General. This test method tests the integ- <br /> gauge.The gauge should be between the valve rity of the liquid-filled interstitial space. There are <br /> and the fitting so it will read the interstitial vac- a number of variables that affect this test, such as <br /> uum when the valve is closed. The automatic interstitial space volume, temperature, water table <br /> vacuum shutoff valve is located at the inlet of and product level in the primary tank. Refer to <br /> the vacuum-producing device and should be Appendix A for specific manufacturers'test proce- <br /> set at a minimum of 10 percent and no more dures. <br /> than 2 inches Hg above the test vacuum. <br /> 4.3.2 Purpose. This general method is used to <br /> 3. Ensure all connections are airtight. test the integrity of the liquid-filled secondary con- <br /> 4. Start the vacuum-generating device, and open tainment of a UST. <br /> the valve. 4.3.3 Description of Test. Liquid is added to <br /> 5. Pull the vacuum to 10 inches Hg. Close the the interstitial space of the tank and the level is <br /> valve. brought up into the interstitial riser.The liquid level <br /> 6. Allow the vacuum to stabilize for a minimum is monitored for a specified period of time. If the <br /> of 5 minutes at the specified vacuum level. If liquid level is maintained, then the containment <br /> a stable vacuum cannot be maintained, test system has passed the test. <br /> equipment shall be inspected for leakage. <br /> �i pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.