My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> 4.3.4 Test Conditions. The primary contain- 4.3.9 Test Procedure. <br /> ment may contain any level of product. Determine L Remove any sensor that may be installed in the <br /> whether the groundwater depth is above the bottom <br /> of the tank.Consult specific manufacturer's proce- <br /> dures in regards to groundwater and performing the 2. Determine and record the groundwater level. <br /> test. No bulk deliveries shall occur within 8 hours 3. Add test liquid to the tank interstitial <br /> prior to conducting or during the test.No dispens- <br /> ing may occur during the test. space, bringing the fluid level into the riser <br /> (standpipe) to the appropriate level based on <br /> 4.3.5 Preparation. Determine the volume of the manufacturer's written procedure. <br /> the tank and identify the test being performed. 4. Document the starting level and start time of <br /> Tank volume information is available from facility the test. <br /> records or the ATG readout. Prepare a monitoring <br /> fluid solution to add to the interstitial space. S. Start the time-measurement device. <br /> 4.3.6 Steel Tanks. Liquid-filled (hydrostatic) 6. Wait the appropriate time according to the <br /> tests on steel tanks require the same fluid as the manufacturer's test procedure. <br /> monitoring fluid. Contact the manufacturer for 7. Document the ending level and ending time of <br /> instructions. the test. <br /> 4.3.7 Fiberglass Tanks. Determine tank size S. Determine and record the groundwater level. <br /> and diameter and apply the appropriate method. 9. Remove liquid added to the tank interstitial <br /> space, and restore the liquid level in the tank <br /> inclu Test Equipment. Test equipment shall interstitial to normal operating condition. <br /> nclude; <br /> 10.Reinstall the sensor so that it is installed within <br /> • monitoring fluid; manufacturer's specifications. <br /> • stopwatch or other time-measurement device <br /> capable of measuring a 1-second increment; 4.3.10 Pass/Fall Criteria. Compare the data to <br /> the manufacturer's pass/fail criteria in Appendix A <br /> • tape measure. to determine if the tank has passed the test. <br /> pei.org <br />
The URL can be used to link to this page