My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 10:00:08 AM
Creation date
7/7/2020 3:29:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health DepartmentUnderground Storage Tank Program Inspection ReportDate:May 28, 2020Facility Address:1605 S EL DORADO ST, STOCKTONFacility Name:El Dorado Gas & MartSUMMARY OF VIOLATIONS(CLASS I, CLASS II, or MINOR - Notice to Comply)RemarksItem #211CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a DO. OBSERVATION: The designated operator employee training for Nabeel Naveed was not current. REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and maintenance of the UST system at least once every 12 months. The training shall be conducted before the individual performs the duties of a facility employees. The training shall include, but is not limited to: 1. Operation of the UST system in a manner consistent with the facility’s best management practices 2. Employee’s role with regard to monitoring equipment as specified in the facility’s monitoring plan 3. Employee’s role with regard to spills and overfills as specified in the facility’s response plan 4. Name of the contact person(s) for emergencies and monitoring equipment alarmsInitial training shall also include a site-specific practical demonstration that provides both sharing information and evaluating knowledge for responding to emergencies, leak detection, monitoring alarms, spills and overfills. At least one of the facility employees present during operating hours shall have current training. CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of the training records to the EHD.This is a minor violation.313HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. OBSERVATION: Little amounts of liquid was found in UDC 3/4 , indicating a leak in the primary containment. REGULATION GUIDANCE: All primary containment for the UST system must be product tight. CORRECTIVE ACTION: Immediately have a properly licensed, trained, and certified contractor repair or replace the failed component(s), under permit and inspection of the EHD if necessary.This is a minor violation.Overall Inspection Comments:Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement documenting the corrective actions that have been or will be taken for each violation, and any supporting paperwork, by 06/27/2020 .To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an appointment, please call (209) 468-3420.Documents provided during inspection: Return to compliance certification form and corrective action statement form.* The asset and liability amounts on the Letter from the CFO have not been updated for the past several years.FA0006185 PR0504388 SC001 05/28/2020EHD 23-01 Rev. 9/20/2019Underground Storage Tank Program OIRPage 6 of 71868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.