Laserfiche WebLink
SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EI Dorado Gas&Mart 1605 S EL DORADO ST, STOCKTON November 06, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 205 CCR 2712(i) Failure to have current UST Monitoring Plan readily accessible at the facility. <br /> OBSERVATION:An approved copy of the monitoring plans were not available for inspection. <br /> REGULATION GUIDANCE:A copy of these plans shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class II. <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions. <br /> OBSERVATION: The facility is not in compliance with the written conditions of the operating permit. <br /> REGULATION GUIDANCE: The owner and operator of underground storage tank(UST)systems shall comply with <br /> all requirements of the permit issued for the operation of the UST system. <br /> CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance. <br /> Immediately restore all monitoring to this system,or remove all fuel from the USTs within 48 hours and immediately <br /> comply with closure requirements. <br /> This is a Class II violation. <br /> 301 HSC 25292.1(a)Failure to operate UST system to prevent unauthorized releases including leaks,spills and overfills. <br /> OBSERVATION: The 87 and 91 underground tank systems at this facility are no longer in use. According to the <br /> owner,Aziz Sher,the monitoring panel was disconnected and removed approximately three weeks ago. The <br /> system is not currently being monitored for leaks. <br /> REGULATION GUIDANCE: The underground storage tank system shall be operated to prevent unauthorized <br /> releases, including spills and overfills. <br /> CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance. <br /> Immediately restore all monitoring to this system,or remove all fuel from the USTs within 48 hours and immediately <br /> comply with closure requirements. <br /> This is a Class II violation. <br /> FA0006185 PR0504388 SC052 11/06/2020 <br /> EHD 23-01 Rev.9/16/2020 Page 6 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />