E
>
EL DORADO
>
1605
>
2300 - Underground Storage Tank Program
>
PR0504388
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 10:00:08 AM
Creation date
7/7/2020 3:29:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0504388
PE
2361
FACILITY_ID
FA0006185
FACILITY_NAME
El Dorado Gas & Mart
STREET_NUMBER
1605
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16703101
CURRENT_STATUS
01
SITE_LOCATION
1605 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> EI Dorado Gas&Mart 1605 S EL DORADO ST, STOCKTON November 06, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 308 CCR 2632(c), 2634(d), 2636(f) Failure of the leak detection equipment to have an audible and visual alarm. <br /> OBSERVATION: The 87 and 91 underground tank systems at this facility are no longer in use. According to the <br /> owner,Aziz Sher,the monitoring panel was disconnected and removed approximately three weeks ago. The <br /> system is not currently being monitored for leaks. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: Correct immediately by having a properly licensed,trained, and certified contractor restore <br /> all monitoring to this system, or remove all fuel from the USTs within 48 hours and immediately comply with closure <br /> requirements. <br /> This is a Class II violation. <br /> 309 CCR 2666(b)(2), 2636(f)(1) Failure to have continuous monitoring that activates audible-visual alarm or stops flow at <br /> dispenser. <br /> OBSERVATION: The 87 and 91 underground tank systems at this facility are no longer in use. According to the <br /> owner,Aziz Sher,the monitoring panel was disconnected and removed approximately three weeks ago. The <br /> system is not currently being monitored for leaks. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: Correct immediately by having a properly licensed,trained, and certified contractor restore <br /> all monitoring to this system, or remove all fuel from the LISTS within 48 hours and immediately comply with closure <br /> requirements. <br /> This is a repeat violation, Class ll. <br /> 311 HSC 25291(b)Monitoring system incapable of detecting leak into secondary containment(pre-Jul 2003). <br /> OBSERVATION: The 87 and 91 underground tank systems at this facility are no longer in use. According to the <br /> owner,Aziz Sher,the monitoring panel was disconnected and removed approximately three weeks ago. The <br /> system is not currently being monitored for leaks. <br /> REGULATION GUIDANCE: The UST system shall be designed and constructed with a monitoring system capable <br /> of detecting leaks from primary containment into secondary containment. <br /> CORRECTIVE ACTION: Correct immediately by having a properly licensed,trained, and certified contractor restore <br /> all monitoring to this system, or remove all fuel from the LISTS within 48 hours and immediately comply with closure <br /> requirements. <br /> This is a Class II violation. <br /> FA0006185 PR0504388 SC052 11/06/2020 <br /> EHD 23-01 Rev.9/16/2020 Page 7 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.