My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
2480
>
2200 - Hazardous Waste Program
>
PR0527200
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/8/2020 3:10:28 PM
Creation date
7/8/2020 3:07:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0527200
PE
2226
FACILITY_ID
FA0007237
FACILITY_NAME
TRACY EXPRESS WASH & LUBE
STREET_NUMBER
2480
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21449002
CURRENT_STATUS
01
SITE_LOCATION
2480 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Used Oil Tank <br /> Containment Integrity Report <br /> For �� � <br /> HMT Inspection <br /> Tracy Express Carwash & Lube <br /> Tracy, CA January 17,2019 <br /> Page 6 of 34 <br /> 2.0 SIGNIFICANT FINDINGS <br /> The following is a summary of the significant findings of the inspection. <br /> HISTORY <br /> This is the first inspection performed at the Tracy Express Carwash & Lube facility in <br /> Tracy, CA on the Used Oil Tank by HMT Inspection. The tank is located inside of the <br /> Lube Bay Basement. Inspection was conducted on one (1) Bulk Storage Tank <br /> containing Used Oil. The Used Oil Tank has been in service and at this location since <br /> 1996 (per client). The Used Oil Tank has a legible nameplate present and was <br /> manufactured by Containment Solutions to meet UL 142 design requirements. The tank <br /> is constructed to normal industry standards. <br /> TANK AS IDENTIFIED BELOW <br /> Configuration and nominal capacity for the Aboveground Storage Tank (AST): <br /> Used Oil Tank = 500 Gallons <br /> Inspection of the aboveground Used Oil Tank and the containment details did not reveal <br /> any areas of defect or anomaly that would require immediate corrective action at this <br /> time. Reference Section 3.0 for the identification, diagram, and area layouts of the tank <br /> and containment details inspected. <br /> ABOVEGROUND USED OIL TANK AND FACILITY <br /> FOUNDATION: The Used Oil Tank rests on a concrete slab inside a building basement <br /> on the southwest side of the facility. The concrete slab foundation beneath the tank has <br /> a tertiary concrete curb surrounding it in case of spilliage. The foundation was found in <br /> acceptable condition. <br /> The tank is not restrained (anchored to the concrete containment floor) and rests on <br /> structural steel supports on the concrete. <br /> 23264311 Used Oil Tank-DTSC Report r4(Rev 0) 2/7/2019 2:38 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.