Laserfiche WebLink
1 <br />' 12 July 2006 <br /> . AGE-NC Project No 95-0130 <br />' Page 8 of 14 <br /> 21 May 2003 <br />' 41 GROUND WATER EXTRACTION-TREATMENT OPERATION <br /> During the first quarter 2006, extraction wells EW-1, EW-2, VW-1C, VW-2A and VW-3A were <br />' each adjusted at the well-heads to continuously extract ground water at a combined flow rate of <br /> approximately 1-2 GPM, however, due to ground water draw-down issues at EW-1 and EW-2, <br /> electric timers were installed to cycle pump operations at alternating 1-hour intervals All extracted <br />' ground water from EW-1,EW-2,VW-I C,VW-2A and VW-3A was routed from the extraction wells <br /> to a 5,000-gallon holding tank, from the holding tank, water was treated by passing through a low <br /> profile air stripper, then through four 2,000 pound media vessels containing liquid phase granular <br />' activated carbon (GAC) Following treatment, water was discharged underground via 1-inch <br /> diameter PVC piping to the City of Stockton sewer system,discharge piping is connected to a sewer <br /> clean-out located in a east section of the site, approximately 100 feet east-northeast of the P&T <br />' system <br /> Based on effluent flow meter readings (Table 9), approximately 312,935 gallons of treated water <br />' were extracted, treated and then discharged to the City of Stockton sewer system between 06 <br /> December 2005 and 14 March 2005 under City of Stockton Department of Utilities Ground Water <br /> Discharge Permit (dated 11 August 2003) <br /> I <br />' 4 2 GROUND WATER EXTRACTION-TREATMENT SAMPLING PROCEDURES <br /> Ground water extraction and treatment influent,intermediate(AFT-AS)and effluent water samples <br /> were collected on a monthly basis from valved ports located upstream(influent),after the air stripper <br /> (intermediate, AFT-AS) and downstream (effluent) of the treatment unit The grab water samples <br /> were collected utilizing 40-m1 EPA-approved VOA vials containing 0 5 ml 18%hydrochloric acid <br />' as a sample preservative and 1-liter amber bottles Care was taken to ensure that visible air bubbles <br /> were not present in the vials after filling and capping Ground water sample containers were labeled <br /> with a sample designation, date, time, and sampler's initials <br /> I <br /> 43 LABORATORY ANALYSIS OF GROUND WATER EXTRACTION AND TREATMENT <br /> Influent,intermediate(AFT-AS)and effluent grab water samples were logged on a chain of custody <br /> form, placed in a chilled container and transported to a California Department of Health Services <br /> (DHS)-certified laboratory to be analyzed for <br /> • <br /> IAdvanced GeoEnvironmental,Inc <br />