Laserfiche WebLink
STANDARD OPERATING PROCEDURE <br />' FIELD SOIL VAPOR MONITORING <br />' A representative soil sample will be collected from each sample interval and placed in a ZiplocO plastic <br /> bag The bag will be sealed and the soil dissaggregated At least ten minutes will be allowed for the soil to <br /> be heated by direct sunlight and for any VOCs in the soil to accumulate in the headspace of the bag <br />' Volatile gases will then be monitored by inserting the probe of a Photovac 2020 phototomzation detector <br /> (PID) The PID is equipped with a 10 b eV lamp which is capable of detecting VOCs at concentrations of <br /> 0 1 parts per million (ppm) The PID will be calibrated on-site using 100-ppmV isobutylene-in-air span gas <br /> (equivalent to benzene)prior to drilling operations PID readings will be recorded in the boring logs <br /> 1 <br /> I <br />�I <br />