My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2020 3:26:56 PM
Creation date
7/16/2020 3:06:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPW Installation and Maintenance Instructions <br /> OPW 61SALP EVR ( Low Profile ) Rotatable Product Adaptors <br /> IMPORTANT : Please read these warnings and use misuse , or improper installation or maintenance . <br /> the assembly instructions completely and carefully OPW shall have no liability whatsoever for special , <br /> before starting . Failure to do so may cause product incidental or consequential damages to any party , <br /> failure , or result in environmental contamination due and shall have no liability for the cost of labor, <br /> to liquid leakage into the soil , creating hazardous freight , excavation , clean up , downtime , removal , <br /> spill conditions . reinstallation , loss of profit , or any other cost or <br /> charges . <br /> IMPORTANT : Check to make sure the unit is intact For any product certified to California 2001 <br /> and undamaged and all parts have been supplied . standards , OPW warrants that product sold by it are <br /> Never substitute parts for those supplied . Doing so free from defects in material and workmanship for a <br /> may cause product failure . period of one year from date of manufacture or one <br /> year from date of registration of installation not to <br /> WARNING -DANGER : Using electrically operated exceed 15 months from date of manufacture by <br /> equipment near gasoline or gasoline vapors may OPW . <br /> result in a fire or explosion , causing personal injury <br /> and property damage . Be sure that the working area THIS WARRANTY IS IN LIEU OF ALL OTHER <br /> is free from such hazards , and always use proper WARRANTIES , EXPRESS OR IMPLIED , AND <br /> precautions . SPECIFICALLY THE WARRANTIES OF <br /> NOTE : At all times when product is in the storage MERCHANTABILITY AND FITNESS FOR A <br /> tank keep the riser pipe capped , so the vapors PARTICULAR PURPOSE , THERE ARE NO <br /> cannot escape into the environment . WARRANTIES , WHICH EXTEND BEYOND THE <br /> DESCRIPTION ON THE FACE HEREOF , <br /> Notice : OPW products must be used in compliance <br /> with applicable federal , state , and local laws and 61SALP Performance Specifications : <br /> regulations . Product selection should be based on This Rotatable Adaptor has been manufactured and <br /> physical specifications and limitations and tested to the following California Specifications : <br /> compatibility with the environment and material to be Rotatable 3600 , Static Torque maximum 108 inch - <br /> handled . All illustrations and specifications in this lbs , <br /> literature are based on the latest production <br /> information available at the time of publication . Preventative Maintenance : <br /> Prices , materials , and specification are subject to Annually , inspect the adaptor for large dents , cracks <br /> change at any time , and models may be or deformation . Replace if necessary . The rotation <br /> discontinued at any time , in either case , without mechanism is not field serviceable . <br /> notice or obligation . <br /> Replacement Parts : <br /> Standard Product Warranty Nipple sealing gasket OPW P/N : H09039M . <br /> OPW warrants that products sold by it are free <br /> from defects in materials and workmanship for a Torque Specification : <br /> period of one year from the date of manufacture by Adapter, 4 " NPSM , 90 ft=Ibs minimum to 110 ftdbs <br /> OPW ( ECO products two years from date of maximum . <br /> manufacture . ) Proof of purchase may be required . <br /> As the exclusive remedy under this limited warranty , <br /> OPW , will at its sole discretion , repair, replace , or Important : Leave these Installation <br /> issue credit for future orders for any product that Instructions with the Station Operator , <br /> may prove defective within the one year date of <br /> manufacture period ( repairs , replacements , or <br /> credits may be subject to prorated warranty for <br /> remainder of the original warranty period , complete <br /> proper warranty claim documentation required . ) <br /> This warranty shall not apply to any product that has <br /> been altered in any way , which has been repaired by <br /> any party other than a service representative <br /> authorized by OPW , or when failure is due to <br />
The URL can be used to link to this page
Your browser does not support the video tag.