Laserfiche WebLink
SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AGS FUEL INC DBA CIRCLE K CHEVRON 1 1490 S MAIN ST, MANTECA March 03, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 314 HSC 25290.1,25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> OBSERVATION: Approximately 1 cup of brine was found in the 87, 91 and diesel fill sumps indicating a leak in the <br /> secondary containment. <br /> REGULATION GUIDANCE: Secondary containment shall be impervious to the liquid and vapor of the substance <br /> contained and constructed to prevent structural weakening as a result of contact with any hazardous substances <br /> released from the primary containment. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to make repairs <br /> to the UST system under permit and inspection of the EHD. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 316 HSC 25290.1(c3), 25290.2(c3)Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> OBSERVATION:Approximately 2 cups of liquid was found in the 87, 91 and diesel fill sumps. <br /> REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation, infiltration, or surface runoff. <br /> CORRECTIVE ACTION: Immediately remove this liquid, make a hazardous waste determination per Title 22 <br /> hazardous waste regulations, and manage accordingly. Immediately contact a properly licensed, trained, and <br /> certified contractor to address the water intrusion into the sumps under permit and inspection of the EHD, if needed. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 4/2/2020. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> Documents provided during inspection: <br /> -EHD class schedule <br /> -Return to compliance certification <br /> -Corrective Action Statement <br /> FA0023750 PR0541436 SCO01 03/03/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />