My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
9484
>
2300 - Underground Storage Tank Program
>
PR0232601
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2024 11:22:08 AM
Creation date
7/20/2020 2:07:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232601
PE
2361
FACILITY_ID
FA0004525
FACILITY_NAME
CHEVRON STATION #372736/2223
STREET_NUMBER
9484
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09055063
CURRENT_STATUS
01
SITE_LOCATION
9484 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�61FTLER-RYAN INC. IVE GR .IOU# 1820. 1789 <br /> D, Results of Testing/Servicing RECE SWRCB,January 2006 <br /> Software Version Installed: <br /> 329 . 01 JUL 13 2018 <br /> Complete the following checklist ENVIRONMENTAL <br /> ❑ Yes 0 o Is the audible alarm operational? -i 4- { ,....' I Ni L-1 <br /> ❑ Yes ® No- Is the visual alarm operational? <br /> ❑ Yes ❑ No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> Yes ❑ No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> pro r operation? <br /> 0 Yes ❑ No' If alarms are relayed to a remote monitoring station,is all communication equipment(e.g.modem)operational? <br /> ❑ N/A <br /> 0 Yes ❑ No' For pressurized piping systems,does the turbine automatically shut down it the piping secondary containment monitoring system <br /> N/A detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check all that apply) <br /> 0 Sump/Trench Sensor, 0 Dispenser Containment Sensor.Did you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? r&d Yes, ❑ No. <br /> ❑ Yes ❑ No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill prevention <br /> m N/A valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If so,at what percent <br /> of tank capacity does the alarm trigger! % <br /> ❑ Yes ® No Was any monitoring equipment replaced?If yes,identify Spec sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all replacement arts in Section E,below. <br /> ❑ Yes ❑ No Was liquid found inside any secondary containment systems designed as dry systems?(Check all that apply) ❑Product []Water. If <br /> yes,describe causes in Section E,below. <br /> ❑ Yes No' Was monitoring system set-up reviewed to insure proper settings?Attach set-up reports,if applicable. <br /> Yes ® No. Is all monitoring equipment operational per manufacture's specifications? <br /> In Sectlon E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Site uses flapper valves inside drop tubes for over fill . There is no <br /> audible or visual alarm panel . <br /> Monitoring System Certification Page 2 of 4 1yro7 <br /> 2 <br />