My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
9484
>
2300 - Underground Storage Tank Program
>
PR0232601
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2024 11:22:08 AM
Creation date
7/20/2020 2:07:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232601
PE
2361
FACILITY_ID
FA0004525
FACILITY_NAME
CHEVRON STATION #372736/2223
STREET_NUMBER
9484
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09055063
CURRENT_STATUS
01
SITE_LOCATION
9484 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
06[rTLER-RYAN INC. GR Job# 1820- 1789 <br /> KA <br /> SWRCB,January 2006 <br /> F. In-Tank Gauging/SIR Equipment: p Check this box if tank gauging is used only for inventory control <br /> ❑ Check this box if no tank gauging or SIR equipment is installed. <br /> This section must be ccmpleted if in-tank gauging equipment is used to perform leak detection monitoring. <br /> QUI. 1 � 101c <br /> Complete the following checklist <br /> es ❑ o Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> ❑ Yes ❑ No' Were all tank gauging probes visually inspected for damage and residue buildup? ' '' <br /> ❑ Yes ❑ No' Was accuracy of system products level readings tested? <br /> ❑ Yes ❑ No' Was accuracy of system water level readings tested? <br /> ❑ Yes ❑ No' Were all probes reinstalled properly? <br /> 11 Yes ❑ No' Were all items on the equipment manufacturer's maintenance checklist completed? <br /> In the Section H,below,describe how and when these deficiencies were or a corrected. <br /> G. Line Leak Detector's(LLD): ❑ Check this box if LLDs are not installed. <br /> Complete the following checklist <br /> Yes ❑ o or equipment start-up or ann5al equipment ce ca on,was a leak simulated verity performance (check all <br /> ❑ N/A that apply)Simulated leak rate: ❑v 3 g.p.h. ❑ 0.1 g.p.h. [] 0.2 g.p.h. <br /> ® Yes ❑ No' Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> Yes ❑ No' Was the testing apparatus properly calibrated? <br /> ® Yes ❑ No' For Mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> ❑ N/A <br /> ❑ Yes ❑ No' For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> 0 N/A <br /> ❑ Yes ❑ No' For electronic LLDs,does the turbine automatically shut off I any portion of the monitoring system is disabled or <br /> 0 N/A Disconnected? <br /> ❑ Yes ❑ No' For electronic LLDs,does the turbine automatically shut off if any portion of the monitoring system malfunctions or <br /> 0 N/A fails a test? <br /> ❑ Yes ❑ No' For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> 0 N/A <br /> 0 Yes ❑ No' 1were all items on the equipment manufacturers maintenance checklist completed? <br /> In the Sec on H,below,describe how and when these da ciencles were or will be corrected. <br /> G. Comments: <br /> Monitoring System Certification Page 3 of 4 12/07 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.