Laserfiche WebLink
S A N D OAQ U I N Environmental Health Department <br /> --COUNTY--- <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MCLANE FOODSERVICE DISTRIBUTION 800 PESCADERO AVE,TRACY September 23,2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 111 CCR 66262.42(a)(c)(d) Failed to comply with uniform hazardous waste manifest exception requirements. <br /> OBSERVATION: The facility did not have exception reports on site for the following Uniform Hazardous Waste <br /> Manifests(UHWM): <br /> -001905125PSC(7/17/2018) <br /> -001965059PSC(9/10/2018) <br /> -000119412DAT(9/24/2018) <br /> -001996292PSC(10/8/2018) <br /> REGULATION GUIDANCE: <br /> (a)A generator who does not receive a copy of the manifest with the handwritten signature of the owner or operator <br /> of the designated facility within 35 days of the date the waste was accepted by the initial transporter shall contact the <br /> transporter and/or the owner or operator of the designated facility to determine the status of the hazardous waste. <br /> (c)A hazardous waste generator who does not receive a copy of the manifest with the handwritten signature of the <br /> owner or operator of the facility to which the generator's waste is submitted,within 60 days from the date that the <br /> hazardous waste was accepted by the initial transporter, shall submit to the department a legible copy of the <br /> manifest,with some indication that the generator has not received confirmation of delivery. <br /> (d)Generators shall submit the information to the department at: DTSC Report Repository, Generator Information <br /> Services Section, P.O. Box 806, Sacramento, CA 95812-0806 <br /> CORRECTIVE ACTION: Locate a copy of the destination facility signed manifests and send a copy to the San <br /> Joaquin County Environmental Health Department(EHD). If the destination facility signed manifests cannot be <br /> found then send to DTSC a copy of each generator signed manifest and a statement that the designated facility <br /> signed copy was not received by the generator. DTSC address is DTSC Report Repository, Generator Information <br /> Services Section, PO Box 806, Sacramento, CA 95812-0806. Provide a corrective action statement to the EHD <br /> within 30 days. <br /> This is a Class II violation. <br /> 303 CCR 66262.34(4)(2) Failed to maintain all communication or alarm systems, spill control,or decontamination <br /> equipment. <br /> OBSERVATION: The emergency eye wash station located in the forklift battery charging area did not have an <br /> adequate flow of water when turned on. <br /> REGULATION GUIDANCE: All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the emergency eye wash station in the forklift battery charging area into proper <br /> working order by repair, replacement or testing. Provide a corrective action statement to the San Joaquin County <br /> Environmental Health Department within 30 days. <br /> This is a Class II violation. <br /> FA0018371 PR0535582 SCO01 09/23/2020 <br /> EHD 22-01 Rev.9/16/2020 Page 7 of 11 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />