PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6ETTLER-RYAN INc. GR Job# 18201786 <br /> Appendix VIE C I.—" R�13 anuary zoob <br /> MONITORING SYSTEM CERTIFICATION 103 201 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, T9fMk9WLoR#ALCode of <br /> Regulations HEALTH nl"p8 <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Arco 7148 Bldg.No.: <br /> Site Address: 3400 N. MacArthur City: Tracy Zip: 95376 <br /> Facility Contact Person: Daryl Lee Contact Phone No.: 415-902-5089 <br /> Make/Model of Monitoring System: TLS-350 Date of Testing/Servicing: 06/19/18 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 91 Tank ID: 87 <br /> In-Tank Gauging Probe. Model: 8 4 7 3 0-l o A m In-Tank Gauging Probe. Model: 847390-109 <br /> 7 Annular Space or Vault Sensor. Model: 794390-302 © Annular Space or Vault Sensor. Model: 794380-302 <br /> 7 Piping Sump/Trench Sensor(s). Model: 794380-208 I I Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> 7 Fill Sump Sensor(s). Model: 79438o-208 © Fill Sump Sensor(s). Model: 794380-208 <br /> 7 Mechanical Line Leak Detector. Model: LD2 0 0 0 IZI Mechanical Line Leak Detector. Model: LD2 0 0 0 <br /> Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> Tank Overfill/High-Level Sensor. Model: SJR m Tank Overfill/High-Level Sensor. Model: VR <br /> Other(specify equipment a and model in Section E on Page 2). ❑ Other(specify equipment a and model in Section E on Page 2). <br /> Tank ID: T)ST, Tank ID: <br /> In-Tank Gauging Probe. Model: 847390-109 ❑ In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 794390-302 ❑ Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: 794380-208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> 7 Fill Sump Sensor(s). Model: 794380-208 ❑ Fill Sump Sensor(s). Model- <br /> 7 Mechanical Line Leak Detector. Model: LD2 0 0 0 ❑ Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> 7 Tank Overfill/High-Level Sensor. Model: VR ❑ Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment t e and model in Section E on Page 2). ❑ Other(specify equipment t e and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> Dispenser Containment Sensor(s). Model: 794380-208 © Dispenser Containment Sensor(s). Model: 794380-208 <br /> Shear Valve(s). © Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> Dispenser Containment Sensor(s). Model: 794380-208 © Dispenser Containment Sensor(s). Model: 794380-208 <br /> Shear Valve(s). ® Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> DispenserlD: Dispenser ID: <br /> Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). ❑ Shear Valve(s). <br /> Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to ver i that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of ge rattng h reports, I have also attached a <br /> copy of the report;(check all that apply): System set-up ❑r Alarm ory report <br /> Technician Name(print): David Rouse Signature: <br /> Certification No.: VR# B44848 ICC#8292530 License.No.: 220793 <br /> Testing Company Name: Gettler-Ryan Inc. Phone No.: 925-551-7555 <br /> Testing Company Address: 6805 Sierra Court Suite G., Dublin CA 94568 Date of Testing/Servicing: 06/19/2018 <br /> Monitoring System Certification Page 1 of 4 12/07 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.