STEP 6: APPLY GREASE TO DROP TUBE <br /> Apply black moly grease to the inside diameter of the <br /> upper drop tube. Make sure coverage is completely <br /> around the tube as shown in Figure 6. <br /> Figure 8 <br /> NOTE:Testable inlet tube must have cable port in <br /> line with float. Testable inlet tube bottoms out on <br /> stop,it does not bottom out on inlet flange. See Fig- <br /> ure 8A <br /> Figure 6 <br /> STEP 7: APPLY GREASE TO POLYPAK SEAL <br /> Ensure that the polypak seal is installed on the inlet <br /> tube with the lip up as shown in Figure 7. Apply black <br /> moly grease to the polypak as shown. Make sure cover- <br /> age is completely around the polypak seal. <br /> Ensure polypak <br /> t` lip is up Cable port must be in <br /> line with float <br /> �;_— --- <br /> Inlet ' \ <br /> Tube p, Polypak % <br /> Figure 8A <br /> Testable Models Only <br /> ------------------ <br /> ply grease <br /> around polypak SEE PAGE 8 FOR INSTRUCTIONS USING THE 71 SO- <br /> TOOL. <br /> Figure 7 <br /> SEE PAGE 9 FOR INSTRUCTIONS USING THE 71 SO- <br /> STEP 8: INSTALL INLETTUBE TOOLC. <br /> Insert the inlet tube into the upper tube until the upper <br /> tube seats against the flange on the inlet tube. Ensure SEE PAGE 10 FOR INSTRUCTIONS USING THE 71 SO- <br /> polypak is inserted evenly and stays in inlet tube TOOLCT. <br /> groove. Note: testable 71 SO models ending with a"T"require the <br /> 71 SO-TOOLCT or modified 71 SO-TOOL or 71 SO-TOOLC <br /> 7 <br />