Laserfiche WebLink
f Cisco Air Systems WORK ORDER INSPECTION SHEET <br /> x rAniorsrreAAfrSomeonrslnce 1973 24 PIR.EMERGENCY SERVICE <br /> +sc�ttCf x}DIStrlGutorofthe Year TOLL FREE 800-813-6763 , K Inge 0/1 Raild <br /> 2001-2008,2012+2016 kiUlr,(li,2(Ierlrl;t^iuy;n5 <br /> CL#479665 <br /> Date of Inspection 2019-W15 <br /> Unit I.D. <br /> Customer Name Quest lndustri es* Model No. N60H-CC <br /> !mix A Yt g ; i <br /> Location 2518 B Bing Way Serial No. NV2909UO6243 <br /> k f A <br /> Customer Contact Benny arcia W:O.# W2400-688875 <br /> laced!C eaned 1 Rebuilt Dur n s t • • • 2 • <br /> Q Re laced!Cleaned/Rebuilt During Visit <br /> Sbl r iresrRe 'al.3Oh`n r uc. laanr 3 .h StrlllRe acres Re"airtk:Gtian in rJ;'d <br /> 1 X j: .Fr i Out ran e Gard-He ace if necessa 39 Ir t., 1st Stage DEsch.Tem Full Load . <br /> 2 X r:, Run Hrs. 62142 Load Hrs. 40 € I/C Press. Loaded <br /> 3 }'?Hours on Coolant 41 Unloaded <br /> 4 ' = Tarc et or Load/Unloa Pressure oil Pressure"-- Oil <br /> 5 Auto Sto 42 =2nd Stage Inlet Temp. <br /> Immed.Sto 43 <br /> 6 ' Full Loa Airend Disc ar e Tem Y, 2nd Stage Disch.Temp. <br /> 9 p 0 44 Unloaded Inlet Vacuum <br /> 7 -' "Full Load Coolant Ince tion Temp. _ Ins ect/Clean Gearcase Breather <br /> 8 Full Load Pkg,Discharge Temp, 45 s <br /> 9 ` Room An Temp. o • 4A SSC D : E �;,F ., <br /> 10 ` Thermostatic Control alve Tem . ' ' tt,�E2 + 3 L i G 12 G 13-G <br /> 11 "Watercooled O/CIN ° 46 Voltage <br /> . <br /> OUT Full Load <br /> 12 - Watercooled A/C <br /> 13 3 Unloaded Sump PSI OUT 47 MotA. F.L. 3f2/V 13t1N <br /> 14 t,- Full Load Separator Pr ssure Drop �� L L <br /> 15 Xi Coolant Filter D/P F to A F1%U T� f311N, <br /> 16 Coolant Type 50 OEt Pum A T Ili r t r /W= <br /> 17 7coolant Sam le Taken 51 • • • hiCP 6e RRiVt 5400 F 1.25 <br /> 18 = Acid Test Performed Yes ❑ No ❑ 52F 1 yx, 400 '110.,A."'120 <br /> 19 :'. Check Coolant Level Yes ❑ No ❑ 53 <br /> 20E 71 7 Inspect for Coolant Le s 54 inspect Contaotors <br /> 21 =' -72 Inspect forAEr Leaks 55 ' =' Ck Electrical Conn. , <br /> 22 Safety Valve Installed/Operational 56 r Control Volta e 012411 23 Inspect Discharge C.V. /MPV ,- • 4 . <br /> 24 -` =inspect Blowdown Valve '7 Package Kw ' <br /> 25 77 Coupling/Belts Conditi n 58 " ' Motor Speed(Max) <br /> 26`' Inspect All Hoses 59` , l Motor V.(Max Speed&Target P.) <br /> 27r; Inspect OWS 60 MotorA.(Max Speed&Target P.) <br /> 28 =' Inspect Coalescing/Pa iculate Filters 61 ' ;DC Bus Voltage(Full Load) -- <br /> 29 Inspect/Clean All Ali,C oled Coolers 62 n; Rotor Clearance <br /> 30 Inspect/Clean Conden ate',Drains 63 s Inspect Heli Effect Sensors <br /> 317777 Inspect/Clean Main/Blower Motors 1 Sta e • • <br /> 32 Grease Main/Fan Motc r 2 Sta e MOT <br /> 33mr2 <br /> Inspect and Clean Scav Orif/Screen mr1 b i m1 I m2 h m1 h m2 DE ODE <br /> 3477 Inlet Filter Condition <br /> 35 ; w PDM Filter Condition <br /> 36 ;_' Dryer Drain Clean <br /> 37 Dryer Condenser Clean Reset Service Timer yes no X PO# <br /> 38X'11 Dew Polnt Returned Part y4es no X Tech Name 'Travis/chris <br /> • <br /> After locking out machine I replac d the oil filter dp switch.Unit is receiving a change coolant filter warning. Warning comes on <br /> when pressure is 20 psi differentia:. Recommend new coolant filter. <br /> N-coolant filter. 54672654 <br /> Travis <br /> i <br />