<br /> VEEDER-ROOT CO MH11766
<br /> 125 POWDER FOREST OR
<br /> PO BOX 2003
<br /> SIMSBURY,CT 06070 USA
<br /> Wireless line leak detectors, Form Nos. 849470-001, -002,-003,-005,PA0263000300,-002,-003.
<br /> Electronic meter register systems,designated EMR3 consisting of one or two electronic meter registers Form No. 8456 followed by 9,followed
<br /> by 2 thru 9,followed by one or more numbers and interconnect box Form No. 8458 followed by 93,followed by 0, 1 or 2,followed by 0 or 1,
<br /> followed by 1 or 2. For use with peripheral equipment as specified by the installation instructions.
<br /> Associated Apparatus,Nonhazardous location,Inventory Measurement System,designated TLS-IB,consisting of Form No.846690-180,-
<br /> 280, -380 or-480 control unit for use with up to eight probes,Form Nos. 8462,8463,8563 or 8570 and/or Mag Flex Probe model 8895 and/or
<br /> Mag Plusl, intrinsically safe for use in Class I, Div. 1,Group D when installed as per Control Drawing Number 331940-014. May be used with
<br /> peripheral equipment as specified by the installation instructions.May be provided with an overfill alarm Form No. 790091-001 with or without an
<br /> acknowledgement switch Form No. 790095-001.
<br /> Associated Apparatus,Nonhazardous location,Inventory Measurement System,designated TLS-50,consisting of Form No.846990-060,-
<br /> 160,-230 or-260 control unit for use with up to six probes,Form Nos. 8462,8463,8563 or 8570 or Mag Plusl,Intrinsically safe for use in Class I,
<br /> Div. 1,Group D when installed as per Control Drawing Number 331940-014. May be used with peripheral equipment as specified in the installation
<br /> instructions. May be provided with an overfill alarm Form No. 790091-001 with or without an acknowledgement switch Form No.790095-001.
<br /> Associated Apparatus,Nonhazardous location,Inventory Measurement System,designated TLS-HLD,consisting of Form No.846990-360
<br /> control unit for use with up to six probes, Form Nos. 8462,8463,8563 or 8570 or Mag Must, intrinsically safe for use in Class I, Div. 1,Group D
<br /> when installed as per Control Drawing Number 331940-014. May be used with peripheral equipment as specified in the installation instructions.
<br /> May be provided with an overfill alarm Form No. 790091-001 with or without an acknowledgement switch Form No. 790095-001.
<br /> Associated Apparatus,Nonhazardous locations,Inventory Measurement System,designated TLS-2,consisting of Form No. 856090-X6Y,
<br /> where X and Y are any character or 856092-060 control unit for use with up to six probes, Form Nos. 8462,8463,8563 or 8570 or Mag Plusl,
<br /> intrinsically safe for use in Class I,Div. 1,Group D,when installed as per control drawing number 331940-014 . May be used with peripheral
<br /> equipment as specified In the installation instructions. May be provided with overfill alarm Form No.790091-001 with or without an
<br /> acknowledgment switch Form No. 790095-001.
<br /> Associated Apparatus,Nonhazardous location,Inventory Measurement System,designated TLS-300 consisting of control unit,Form No.
<br /> 84859X-XXX where X can be any character may be connected to thirty-two intrinsically safe sensors or probes. May also be provided with overfill
<br /> alarm Form No. 790091-001 with or without acknowledgement switch Form No, 790095-001.The probes and sensors have been evaluated for use
<br /> in Class I,Div. 1,Group D hazardous locations when connected in accordance with control drawing number 331940-013.The following probes and
<br /> sensors are suitable for this system:
<br /> Magnetostrictive probes, Basic Form Nos. 8462,8463,8563,8570;
<br /> Liquid or Vapor Sensors, Basic Form Nos.7943 with or without 80 or 90 maybe be followed by three characters;
<br /> 2 to 1 Sensor Input Boxes, Form No. 857390-102;
<br /> Oil/Water Separator Sensor, Basic Form No. 7946;
<br /> UL Listed Submersible Pump, Models PC or PAGC;or Mag Plusl.
<br /> Liquid level gauge/leak detection system,designated TLS-450/8600.Associated Apparatus,non-hazardous location,liquid level
<br /> gauge/leak detector control unit, Form No.8600,followed by 90,followed by 1 followed by 00, provides intrinsically circuits for use in Class I, Div.
<br /> 1,Group D, may be used with up to 16 intrinsically safe probes/sensors per USM Module when installed in accordance with Control Drawing
<br /> 331940-008.Suitable Intrinsically Safe Devices for use in Class I, Div. 1, Group D are 2 to 1 Sensor Input Box,Form No. 857390-102 only