Laserfiche WebLink
331847-001,331847-002,332374-001 or 332374-002,or ISD Pressure Sensor Form No. 86119X-XXX or Digital pressure line leak,Form No. <br /> 332681-XXX; or Discriminating dispenser pan,containment pump,interstitial sump,hydrostatic and position sensitive sensors, Form <br /> No.794380 followed by-208, -209, -301,-302,-303-304,-322, -323, -343, -344,-345,-352,-430 or Form Nos. 794390,followed by-401,- <br /> 404, -407, -409,-420,-449,-460; or CSTP Liquid Switch,UL Listed Veeder-Root Submersible Pump Basic Models PC or PAGC; or Vapor <br /> sensor,Form No. 794390-700 or Solid state discriminating sensors,Form No. 794380,followed by-320, -350, -360,-361,-362;or Solid <br /> state dispenser pan and containment sump sensors, Form No. 794380,followed by-321,-351; or Ground water sensors,Form No. <br /> 794380,followed by-621, -622, -624; or Mag Plusl.The control unit may also be provided with the following equipment for use in non-hazardous <br /> locations: Overfill alarm, Form No. 790091-001,with or without an acknowledgement switch Form No. 790095-001 or OSM Module, Form No. <br /> 865090-100,-101, -102,-103 or-104,up to four provided,module provides intrinsically safe circuits for combinations described above or I/O <br /> Modules,Form No. 865090-200,-210,-211,-212,-220,-221 or-222, up to four provided or Communication Modules, Form Nos. 865090- <br /> 301,-302,-303, -304, -330,-331,-332,-333,-339,-340, -341 or-401 may be used with peripheral equipment as specified in the installation <br /> instructions.The following robes and sensors are suitable for this system, <br /> Associated Apparatus,Non-Hazardous Location,Inventory Measurement System,Control unit Model TLS-RF,Form No.332242-001,-002 <br /> for use in non-hazardous locations,provides intrinsically safe outputs for use in Class I, Div. 1,Group D when used and installed as specified in the <br /> Installation Manual, 577013-839 or 577013-964. May also be connected to non-hazardous locations peripheral equipment as specified in the <br /> installation manuals. <br /> Intrinsically Safe Apparatus,Class I,Div. 1,Group D,Inventory Measurement System,Battery Box,Part Number 332425-001 only for <br /> connection to the intrinsically safe transmitter, Part Number 332235-001,which is in turn only for connection to one: <br /> Intrinsically safe probe,Form No. 84739,85639,84689,84629 or 84639 all followed by 0 or 1,followed by 0, 1,2,3,4, 5,6 or 7,followed by 00 <br /> to 17 inclusive or 99;or Form No.857080 followed by 1 or 2,followed by 0, 1,or 2,followed by 1 or 2; or <br /> CCVP-Form No.861290-XXX; or <br /> ISD Flow Meter and Balanced Flowmeter-Part Nos. 331847-001,331847-002, 332374-001 and 332374-002; <br /> ISD Vapor Pressure Sensor-Part No.86119X-XXX; or Mag Plusl. <br /> All suitable for use in Class I,Group D when used and installed as specified in the Control Drawing 331940-012. <br /> Liquid-level Gauge Accessory,Inventory Measurement System,Battery Box,Part No. 332425-001,Intrinsically Safe Devices,Class I, Div. <br /> 1,Group D only for connection to the Model Mag XL-RF intrinsically safe transmitter,Part No.333062-XXX(where XXX represent alphanumeric <br /> characters unrelated to safety certification).The Mag XL-RF intrinsically safe transmitter provides intrinsically safe outputs for use in Class I Group <br /> D as specified in Control Drawing,331940-009. <br /> Associated Apparatus, Nonhazardous location,Inventory Measurement System,designated TLS-350 or TLS-350-PC or TLS-3501, <br /> consisting of control unit Form No. 84709 followed by 0, 5 or 7,followed by 0, 3,4,5 or 6,followed by 0 or 2,suffixed 2 or 4;or designated TLS- <br /> 35OR or Simplicity consisting of control unit Form No. 84829 followed by 0, 1, 2,3,or 5,followed by 0 or 1,followed by 0 or 2,followed by 2 or 4 <br /> or designated 4000 consisting of control unit Form No.848390,followed by 5 or 8,followed by 00; May be provided with: Overfill Alarm Form No. <br /> 790091-001 with or without an Acknowledgement Switch Farm No.790095-001; Remote Display Unit,Form No.8478,followed by 8 or 9,followed <br /> by 0,followed by 1 or 2,followed by 1 or 2,followed by 1 or 2.Form No. 847090-1 followed by 0, 1 or 2,followed by 2;The control unit may be <br /> provided with a combination of Plug-in Modules Form Nos.847490-001, -100, -101,-102,-103,-104,-105, -106, -109,-110,-111,-202,-204, - <br /> 206,-207,-208,-209,-210,-300,-301,-302,-303,-304, -305, -306, -309,-315,-316,-317,-326,-327,-340,-350, -360, -370,-380,-400,- <br /> 401,-410, -420,-430,-431,-480 or Form Nos. 329359-001,329360-001,332250-001 (only one can be provided), or 332451-001. Form No. <br /> 847090-1,control unit may additionally be provided with Form Nos. 847490 107 or-108 plug-in modules.Advanced Application Module Form No. <br /> 849090 followed by 5 or 8,followed by 00 to 16 inclusive and up to 16 liquid sensors; Form No. 7943 followed by 8 or 9,followed by 0,followed by <br /> -205,-301, -302, -333,-401,-404,-407,-409 or-420;TLS-RF Console,up to four may be connected to intrinsically safe field wiring terminals but <br /> cannot be placed in the hazardous location.TLS-350 Consoles may connect up to 64 of the intrinsically safe apparatus below.These devices have <br /> been evaluated for use in Class 1,Div. 1,Group D hazardous locations when connected to the above in accordance control drawing number <br /> 331940-011.The following probes and sensors are suitable for this system: <br /> Magnetostrictive probes, Basic Form Nos. 8462, 8463,8563,8570; <br /> Liquid or Vapor Sensors, Basic Form Nos. 7943 with or without 80 or 90 maybe be followed by three characters; <br /> CCVP,Form No. 861290-XXX; <br /> ISD Flow Meter, Part No. 331847-XXX or 332374-XXX; <br /> Vapor Pressure Sensor, Part No. 331946-XXX or basic Form No. 8611; <br /> Pressure Line Leak Detectors(PLLD), Basic Form Nos.8484; <br /> Vacuum Sensors, Form No.332175-XXX; <br /> 2 to 1 Sensor Input Boxes, Form No.857390-102; <br /> Oil/Water Separator Sensor, Basic Fom No. 7946; <br /> UL Listed Submersible Pump,Models PC or PAGC; Mag Flex Probe Model 8895. <br />