Form No.7943XX-333; where X may be any character,Intrinsically safe device for use in Class I,Div. 1,Group D and Class I Zone 0 Group IIA;
<br /> Hazardous Locations when installed in accordance with manual 576013-616.
<br /> Oil/Water separator sensors, Form Nos. 7946XX-XXX;where X may be any character,intrinsically safe device for use in Class I, Div. 1,Group
<br /> D and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 577013-737.
<br /> Dispenser pan sensors, Form Nos. 7943XX 32X; where X may be any character,intrinsically safe device for use in Class I, Div. 1,Group D and
<br /> Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-306.
<br /> Containment sump sensors, Form Nos.794380-35X; where X may be any character,intrinsically safe device for use in Class I, Div. 1,Group D
<br /> and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-306.
<br /> Discriminating interstitial sensors,Form Nos. 79438X-343,where X may be any character,intrinsically safe device for use in Class I,Group D
<br /> and Class 1, Zone 0,Group IIA Hazardous Locations when installed in accordance with manual 576013-826.
<br /> MicroSensors, Form Nos. 79438X-344; where X may be any character,intrinsically safe device for use in Class I,Div. 1,Group D and Class I
<br /> Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-285.
<br /> Discriminating interstitial sensors,alternate Fluid cable, Form Nos. 79438X-345;where X may be any character,intrinsically safe device for
<br /> use in Class I, Div. 1,Group D and Class I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-826.
<br /> 2 to I Sensor Input Box,Form No. 857390-102 only for use with Sump,Position Sensitive and Hydrostatic Sensors,Form Nos. 794380 followed
<br /> by-208, -209, -301,-304,-323,intrinsically safe device for use in Class I,Div. 1,Group D and Class I Zone 0 Group IIA; Hazardous Locations
<br /> when installed in accordance with manual 577013-869.
<br /> Interstitial sensors,Form Nos. 7943XX-40X;where X may be any character, intrinsically safe device for use in Class 1,Div. 1,Group D and Class
<br /> I Zone 0 Group IIA; Hazardous Locations when installed in accordance with manual 576013-617.
<br /> Mag Flex Probe, Model 8895 intrinsically safe for use in Class I,Group D; Class I Zane 0 AEx is IIA T4; hazardous locations when installed in
<br /> accordance with installation manual 577014-037.
<br /> Last Updated on 2013-12-03
<br /> Questions? Print this page Terms of Use Page Too
<br /> © 2013 UL LLC
<br /> When the UL Leaf Mark is on the product,or when the word"Environment"is included in the UL Mark, please search the UL Environment database
<br /> for additional information regarding this product's certification.
<br /> The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
<br /> under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
<br /> Service.Always look for the Mark on the product.
<br /> UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide
<br /> Information,Assemblies,Constructions,Designs,Systems,and/or Certifications(flies)must be presented in their entirety and in a non-misleading
<br /> manner,without any manipulation of the data (or drawings).2.The statement"Reprinted from the Online Certifications Directory with permission
<br /> from UL"must appear adjacent to the extracted material.In addition,the reprinted material must include a copyright notice in the following
<br /> format:V 2013 UL LLC".
<br />
|