ITEM #16 & 17 <br /> Short Form Specification 3. Tank shall be capable of storing the following products: <br /> The contractor shall provide the appropriate single,double or triple-wall a. Diesel fuel oils for oil burning equipment at , <br /> fiberglass storage tank and accessories as indicated on tank drawings. temperatures notto exceed 150W. <br /> Capacity, dimensions and fitting locations will be indicated on tank b. Gasoline,jet fuel,aviation gasoline,motoroil <br /> drawings. Tanks shall be manufactured by Containment Solutions, (new orused),kerosene,diesel motorfuel at <br /> Inc.The tank must be tested and installed according to manufacturer's ambient temperatures. ' <br /> current installation instructions. c. Alcohol-gasoline blend motorfuels at ambient <br /> Long Form Specification temperatures: <br /> Part l: General Gasoline-ethanol blends with up to 100%ethanol. <br /> 1.01 Quality Assurance <br /> Gasoline-methanol blends with up to 100% ' <br /> methanol. <br /> A. Acceptable Manufacturers: d. Oxygenated motor fuels at ambient temperatures <br /> Containment Solutions,Inc.,(CSI),Conroe,Tezas with up to 20%(by volume)methyl tertiary butyl ether <br /> B. Governing Standards,as applicable: (MTBE),ethyl tertiary butyl ether(ETBE),di-isopropyl ' <br /> 1. Underwriters Laboratories Inc.Standard 1316,Glass-Fiber ether(DIPE),tertiary butyl alcohol(TBA),tertiary amyl <br /> Reinforced Plastic Underground Storage Tanks for Petroleum methyl ether(TAME),ortertiary amyl ethyl ether(TAEE). <br /> Products,Alcohols,and Alcohol-Gasoline Mixtures. e. Biodiesel-diesel blends with up to 100%biodiesel(BI 00 <br /> 2. Underwriters Laboratories of Canada standard ULC-5615, per ASTM)at ambient temperatures. , <br /> Reinforced Plastic Underground Tanks for Flammable& C. Materials <br /> Combustible Liquids. 1. The tank shall be manufactured as a matrix of premium <br /> 3. National Fire Protection Association codes and standards: resin,glass fibers and silane-treated silica that together <br /> a. NFPA 30 Flammable and Combustible Liquids Code result in a composite providing improved corrosion ' <br /> protection. <br /> Garages <br /> ges Code <br /> b. 30A Motor Fuel Dispensing Facilities and Repair 2. The tank inner wall shall be fabricatedagainst a mold to <br /> Gara <br /> produce anon-air inhibited and high gloss laminate to <br /> c. NFPA 31 Installation of Oil-Burning Equipment Standard provide a fully cured inner surface without the need of wax <br /> 4. City of New York Department of Buildings M.E.A.,71-85-M coats,a low coefficient of friction and a natural resistance to <br /> 5. American Concrete Institute standard ACI 318,Building Code the build-up of algae or other contamination on the surface. <br /> Requirements for Structural Concrete. Wax and wax resin coatings cannot be used to achieve full <br /> surface cure on tank shells and endcaps. , <br /> 1.02 Submittals D. Dimensional Requirements(refer to Containment Solutions <br /> Contractor shall submit_copies of: shop drawings, manufacturer's literature) <br /> productbrochures,installation instructions and calibration charts. 1. Nominal capacity of the tank shall be—gallons/liters. <br /> Part It.Products 2. Nominal outside diameter of the tank shall be—feet. , <br /> 2.01 Double-Wall or Triple-Wall 3. Nominal overall length of the tank shall be—feet. <br /> Fiberglass Underground Storage Tanks E. Monitoring Capabilities <br /> A. Loading Conditions-Tanks shall meet the following design 1. Double and triple-wall tanks shall have a monitoring <br /> criteria: space between the walls to allow for the free Flow and ' <br /> 1. External hydrostatic pressure:Buried in ground with containment of leaked product from the primary tank.The <br /> 7'of over burden over the top of the tank,the excavation monitoring space shall provide equal communication in all <br /> fully flooded and a safety factor of 5:1 against general directions. <br /> buckling. 2. The following continuous monitoring conditions shall be <br /> 2. Surface Loads:When installed according to manufacturer's compatible with the cavity between the inner and outer <br /> current installation instructions,tanks shall withstand tanks: <br /> surface HS-20 axle loads a. Vented to atmosphere <br /> (32,000 lbs/axle). b. Vacuum-5 psig maximum ' <br /> 3. Internal Load:Primary and secondary tanks shall withstand c. Positive air pressure(5 psig maximum) <br /> 5 psig(35 kPa)air pressure test with 5:1 safety factor. d. External hydrostatic pressure-Tmaximum <br /> 4. Tanks shall be designed to support accessory equipment groundwater head pressure over tank top <br /> such as heating coils,ladders,drop tubes,etc.when ' <br /> installed according to manufacturer's recommendations and 3. Tanks 6'diameter and larger shall have an integrally <br /> limitations. mounted annular space reservoir installed on the tank <br /> for factory-installed brine and continuous hydrostatic <br /> B. Product-Storage Requirements monitoring.The reservoir shall be constructed of fiberglass <br /> 1. All primary tanks must be vented.Tanks are designed for reinforced plastic materials and be included in the tank ' <br /> operation at atmospheric pressure only,except for use with warranty. <br /> vapor recovery systems at a pressure or vacuum not to 4. The monitoring fitting for the monitoring space shall be <br /> exceed 1 psig Q kPa). a 4"NPT fitting. <br /> 2. Tanks shall be capable of storing liquids with specific gravity 5. The monitoring system shall be capable of detecting a ' <br /> up to 1.1. breach in the inner and outer tank under the following <br /> installed conditions: <br /> 17 SPECIFICATIONS ' <br />