Laserfiche WebLink
I <br /> 1. H. KLEINHI-DER &ASSOCIATES <br /> o The design and engineering of a ground water extraction <br /> system to be installed in a select existing ground <br /> water monitoring well (MW--1 or MW-7) . <br /> o The use of computer modeling of the ground water <br /> extraction system. Modeling should be used' to assess <br /> the effects of various pumping rates; estimate the <br /> ^' potential radius of capture; and assist in the <br /> selection of the appropriate pump and piping dimensions . <br /> o Evaluation of proven ground water treatment systems for <br /> petroleum hydrocarbon recovery, principally carbon <br /> adsorption or air stripping treatment systems. <br /> o The appropriate location for reinjection of treated <br /> ground water. <br /> o The collection and chemical analysis of ground water <br /> samples to evaluate the ground water treatment system, <br /> and insure adequate treatment. <br /> _ J.H. Kleinfelder & Associates recommends that a copy of this <br /> report be submitted to the San Joaquin County Local Health <br /> Aistrict and The California Regional Water Quality Control Board <br /> for their review and consideration. <br /> 19:531 16 <br />