Laserfiche WebLink
a. , <br /> KLEINFELDER & ASSOCIATES <br /> o Major equipment jtypes with approximate capacities, sizes and <br /> ..K construction materials. <br /> Y, <br /> o Process flow sheets with mass balances. <br /> o Operational description of process units or other facilities, <br /> including general piping and instrumentation layouts. <br /> o Estimates of material or equipment quantities required. <br /> o A description of the structural concepts for any needed <br /> t facilities. <br /> : . o Identification of construction material requirements, other than <br /> equipment. <br /> o A general deocription of the utility requirements and the <br /> rationale for those needs. <br /> o An evaluation of potential construction problems, risks, and <br /> solutions. <br /> k <br /> o Right-of-wny requirements (if any). <br /> i <br /> o Identification of additional engineering data (if any) required <br /> to proceed with the design. <br /> o Performance standards to define levels of clean-up required to <br /> complete the remedial action. <br /> 3.9 REKEDIAL ALTERNATIVE CONSTRUCTION AND START-UP <br /> OBJECTIVE <br /> The objective is to implement the construction and start-up phases of the <br /> selected remedial treatment system. <br /> j <br /> 33-87--887 20 <br /> EM�o <br /> j <br /> i <br />