Laserfiche WebLink
' 3 0 CONSTANT RATE TEST DATA <br /> Antecedent (static) water level data was measured prior to the test on August 19, 2000 The <br />' drawdown, or discharge, portion of the constant rate pump test began at 14 30 hours on August <br />' 19, 2000 The pump was turned off 17-hours, 5-minutes (1,025 minutes) later at 07 25 hours on <br /> August 20, 2000 <br />' DEPTH TO WATER MEASUREMENTS <br /> Well Before Test At End of Test Casing <br /> Date/Tine Time Depth to Water Time Depth to Water Elevation <br /> EW-1 13 52 1248 07 08 1842 2595 <br /> MW-5 1402 1290 0709 1304 2633 <br /> P-3 1404 1274 07 10 1280 2626 <br /> P-5 1400 1240 07 15 1245 2594 <br /> P-2 1405 1266 07 12 1270 2617 <br /> P-4 1406 1304 07 13 1307 2668 <br /> P-1 1405 1266 07 11 1270 2633 <br /> MW-1 1418 1343 0724 1345 2709 <br /> MW-2 1422 13.00 07.26 1301 2666 <br /> MW-3 1413 12.39 07-17 1240 2596 <br /> MW-4 1420 1274 0727 1274 2633 <br /> MW-6 1416 13 32 0720 1492 2633 <br /> MW-13 13 14 12 13 07.30 12 15 2556 <br /> MW-14 13 17 1222 0731 1222 2561 <br /> MW-15 1320 1239 0735 1240 2578 <br /> Potentiometric surface maps for these date are presented in Figure 2 (Pre-Test) and in Figure 3 <br /> (Near End of Test) <br /> Intermediate depth monitoring well MW-11 was obstructed at 10 44 feet below the casing tap <br /> Intermediate depth momtormglg well MW-8 was obstructed at an unmeasured depth below the <br /> casing top <br /> i <br /> H2 0 GE 0 L A GROUND WATER CONSULTANCY <br />