My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_DRAFT ENVIRONMENTAL IMPACT REPORT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2450
>
2900 - Site Mitigation Program
>
PR0506303
>
ARCHIVED REPORTS_DRAFT ENVIRONMENTAL IMPACT REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2020 5:02:58 PM
Creation date
7/23/2020 4:33:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
DRAFT ENVIRONMENTAL IMPACT REPORT
RECORD_ID
PR0506303
PE
2965
FACILITY_ID
FA0001086
FACILITY_NAME
MANTECA PUBLIC WORKS
STREET_NUMBER
2450
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
24130050
CURRENT_STATUS
01
SITE_LOCATION
2450 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
736
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IMPACT Public Services and Utilities—Increased Generation of Solid Waste. The proposed project would not <br /> 4.10-2 substantially increase the amount of solid waste generated at the WQCF related to the total capacity of the <br /> Forward Landfill. Waste generated by the WQCF from implementation of the proposed project would be <br /> less than 0.1%of the Forward Landfill's permitted capacity. In addition, staff at the Forward Landfill have <br /> indicated that the landfill has sufficient capacity to accommodate increased solid waste demands from the <br /> WQCF at project buildout. Therefore, the project's solid waste impact would be less than significant. <br /> Approximately 10 additional staff would be needed to operate the WQCF at plant buildout in 2020, and five <br /> additional staff would be needed at partial plant buildout in 2010. The CIWMB provides an average per-capita <br /> solid-waste disposal rate for business types including utilities like wastewater treatment plants(CIWMB 2004). <br /> Solid-waste disposal rates for utilities are estimated at 0.3 ton per employee per year. Using the waste disposal <br /> rate of 0.3 ton per employee per year for 10 employees, 3 tons of waste(or approximately 83 cubic yards)would <br /> be generated annually by these employees in 2020. One and one-half tons of waste would be generated annually <br /> by five additional employees in 2010. <br /> Waste screenings,grit, and biosolids are generated by the WQCF and trucked to the Forward Landfill for <br /> disposal. Annually,the WQCF currently generates 104 cubic yards of waste screenings, 52 cubic yards of grit, <br /> and 638 tons(approximately 548 cubic yards)of biosolids (Shannon,pers. comm.,2006). Estimated screenings, <br /> grit, and biosolids generation rates are assumed to increase proportionally to the increase in plant capacity from <br /> 9.87 mgd ADWF to 27 mgd ADWF (approximately 174%). Therefore,the proposed project would increase <br /> annual screenings, grit, and biosolids generation rates to 285 cubic yards of waste screenings, 142 cubic yards of <br /> grit, and approximately 1,502 cubic yards of biosolids. <br /> Solid waste generation rates of 2,012 cubic yards per year would not be reached until full plant buildout in 2020. <br /> Much lower generation rates would occur at project initiation in 2008,with gradual increases in the rate until full <br /> buildout. The Forward Landfill has approximately 29.38 million cubic yards of available capacity,which is <br /> estimated to last through 2017 (Kennedy,pers. comm.,2006). Staff at the landfill indicted that plans for future <br /> expansion of the landfill are not yet under way and would not occur until remaining capacity is less than 7 years. <br /> Assuming an annual solid waste disposal rate of 2,012 cubic yards,the proposed project would increase the <br /> amount of solid waste generated by a total of approximately 20,120 cubic yards through 2017. As such,waste <br /> generated by the WQCF from implementation of the proposed project through 2017 would be less than 0.1%of <br /> the Forward Landfill's permitted capacity. <br /> Additionally,the proposed project would comply with all federal, state, and local statutes and regulations related <br /> to solid waste reduction and recycling and the project would be consistent with City general plan policies related <br /> to source reduction and recycling(Policy PF-P-31). <br /> Because the waste generated by the WQCF from implementation of the proposed project would be less than 0.1 % <br /> of the Forward Landfill's permitted capacity, and the proposed project would not violate federal, state, or local <br /> statutes and regulations related to solid waste,the project would result in less-than-significant solid waste <br /> impacts. <br /> IMPACT Public Services and Utilities—Increased Demand for Electricity and Natural Gas. Implementation of <br /> 4.10-3 the proposed project would increase demand for energy in the city. However, the energy demands created <br /> by the project would not be substantial in relation to the total energy currently supplied by PG&E in its <br /> northern and central California service area or total energy demands expected in the future, and proposed <br /> energy improvements would be required to comply with existing City, PG&E, and applicable Uniform <br /> Building Code requirements. Therefore, this impact would be less than significant. <br /> Average electricity demand at the WQCF is 17,386 kWh per day(or 724 kW per day), and average natural gas <br /> demand is 27.1 therms per day(Shannon,pers. comm.,2006). Estimated future demands for electricity and <br /> natural gas are assumed to increase proportionally to the increase in plant capacity from 9.87 mgd ADWF to <br /> Manteca WQCF and Collection System Master Plans EIR EDAW <br /> City of Manteca 4.10-7 Public Services and Utilities <br />
The URL can be used to link to this page
Your browser does not support the video tag.