My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 3:43:10 PM
Creation date
7/27/2020 2:14:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AMENDED <br /> DED <br /> 000 <br /> SANJ O A Q U I N Environmental Health Department <br /> I i Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> ARCO 05450 1617 W FREMONT ST , STOCKTON July 15 , 2019 <br /> UST System Observations <br /> F314 HSC 25290 . 11 25290 . 2 , Failed to have secondary containment or secondary containment not tight ❑ V ❑ R ii COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed , and properly disposed of (pre-Jul 2003) ❑ V ❑ R ❑ COS <br /> 316 HSC 25290. 1 (c3) , Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R ❑ COS <br /> 25290 .2(c3) <br /> 317 CCR 2636, 2643(c) (1 ) , Line leak detector (LLD) not installed ❑ V ❑ R ❑ COS <br /> 2666 <br /> 318 CCR 2666(c) , 2643(c) (1 Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch ❑ V ❑ R ❑ COS <br /> 319 CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons , no means to keep it empty, or failed to be tested ❑ V ❑ R ❑ COS <br /> 2665 , 2712 <br /> 320 CCR 2635, 2637.21 Failure to comply with the installation , inspection , or record keeping of the overfill prevention ■ V ❑ R ❑ COS <br /> 2665, 2712 <br /> L321 CCR 2635(b) (2) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717 . 1 (8) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717. 1 (f) Deposited petroleum into a red tagged UST ❑ V ❑ R ❑ COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 11 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 HSC 25298; CCR 2670, Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2672 <br /> 330 CCR 2636(f) , 2666(c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R ❑ COS <br /> 2666 <br /> 331 CCR 2630(d) 1 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e. , failure to remove test boot) . ❑ V ❑ R ❑ COS 1 <br /> 332 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666 b&e <br /> 333 CCR 2635, 2636(b) , Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> Single -Walled Non - Pressurized Piping <br /> 401 CCR 2636(a)(3) , 2641 (b Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984) . ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d) , 2661 (f) Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643(e) , 2661 (f) Biennial 0. 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> FA0003606 PR0231923 SCO01 07/15/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.