My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2021 8:56:03 AM
Creation date
7/27/2020 2:27:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
ARMY COURT
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
02
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />ARMY COURT <br />1624 ARMY CT, STOCKTON <br />October 25, 2019 <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />101 <br />HSC 25284; CCR 2711(d) Failed to obtain a permit to operate from the EHD including but not limited to unpaid <br />permit fees. <br />A permit to operate the UST system has not been issued. No person may own or operate an UST unless a permit <br />for its operation has been issued by the local agency to the owner or operator of the UST system. Immediately <br />obtain a permit to operate a UST system from the EHD. An "Operating without a Permit' penalty applies. <br />This is a Class I violation. <br />103 <br />HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br />Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br />are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) <br />at http://cers.calepa.ca.gov/, and upload the required documents. <br />Financial responsibility documents have not been submitted to the EHD. The most recent financial responsibility <br />documents in CERS are dated [DATE]. Current financial responsibility documents are required to be submitted <br />annually. Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, <br />and upload the required documents. <br />This is a minor violation. <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Tank Information forms are not current in the California Environmental Reporting System (CERS). <br />-The diesel tank manufacturer is not listed. <br />- The form states no striker plates installed <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required information, and submit for review by the EHD. <br />This is a Class II violation. <br />105 <br />CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. <br />-The Monitoring plan contain inaccurate name of persons responsible. <br />-The Piping system is in correctly stated in monitoring plan and tank form <br />The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br />into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a minor violation. <br />FA0003777 PR0231014 SCO01 10/25/2019 <br />EHD 23-01 Rev. 9/20/2019 Page 4 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page