Laserfiche WebLink
-�z <br /> JAN 2 2019 <br /> 4 a ;ia <br /> HOW TO LOCATE THE POSITION OF THE <br /> 71 SO AT 95% TANK CAPACITY Measuring Stick <br /> The length of the upper tube and the placement of '° <br /> the 71 SO valve body determine the shut-off point. <br /> Following the standard instructions for the OPW <br /> 71 SO will provide for initial shutoff at 95% . In all <br /> cases , the upper tube length must be a minimum of <br /> 6- 1 /2" plus the length of the riser pipe . All length r <br /> measurements are in inches . Riser Pipe <br /> with Face <br /> INSTRUCTIONS Seal Adaptor (A) <br /> To Tank (g ) <br /> Ot S � i 1 . ) Find tank capacity (in gallons ) from tank Top ( 1 . t7 . ) To Tank <br /> calibration chart provided by tank manufacturer. Bottom <br /> 0. NZ3y 2. ) Calculate 95% of capacity . <br /> 6 = 1l2" <br /> , Cja 43 ( y, 3 . ) Locate the 95% volume number on the tank - <br /> calibration chart. <br /> Figure 1 <br /> tot; '1114 4 . ) Find the dipstick number (X) which corresponds <br /> to the 95 % tank volume. And , find the dipstick <br /> z ti1G " number (Y) which corresponds to the EXAMPLE <br /> 100%volume . 1 . ) For an Owens-Corning Model G -3 Fiberglass® <br /> Tank Calibration Chart: <br /> 5. ) Subtract the dipstick number (X ) from the tank Tank Capacity - 10 , 000 gal . , nominal 9 ,403 gal. <br /> diameter (Y ) to find the upper tube reference NOTE : Use actual capacity only <br /> number (Z) . <br /> (Y) - (X) _ (Z} 2 . ) 95% of actual tank capacity = 0 . 95 x <br /> 1Z 6. ) Subtract 2" from (Z) to find the upper tube depth 9403 gal . = 8933 gal . <br /> (C )• 3 . ) The closest number which is less than 8933 gal . <br /> (Z) - 2" = C Is 8910 gal . Choosing the closest number less <br /> ) than 95% of actual capacity ensures that the <br /> 7 . C less than 6- 1 / 2" ? initial shutoff will occur when the tank is no more <br /> than 95% full . <br /> NO Upper tube length is C plus the distance <br /> from the top of the Face Seal Adaptor 4. ) The calibration chart reading of 8910 gal . <br /> installed on the riser pipe to the inside , top corresponds to a dipstick measurement of 82" . <br /> lip of the storage {A}. <br /> 5 . } Dipstick number (X) = 82" <br /> Upper Tube Length = C + (A ) Tank diameter (Y ) = 92" <br /> (Y ) - (X } _ (Z ) (92 "- 82" = 10") <br /> YES Upper tube length is 6- 1 /2 " plus the riser (Z) = 10" <br /> pipe measurement (A ) . <br /> 7 . ) (Z) - 2" = C ( 10" - 211 = 8 <br /> Upper Tube Length = 6 - 112 " + (A) C = 8 <br /> IN <br /> NOTE : You must find the actual tank capacity 7 . ) Is 8" less than 6- 112"l <br /> number that correlates to the 6 .112" + ( A) depth <br /> for the station records. This number may also NO Measure the distance from the top of the <br /> be used for the purposes of calibrating an FSA400 Face Seal Adaptor installed on the <br /> electronic tank level system. riser pipe to the inside , top lip of the storage <br /> tank and obtain measurement (A). <br /> ® Registered TA , • Owens Corning Fiberglass Corporation Upper tube length = C + (A) <br /> 64 <br />