My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 1:58:58 PM
Creation date
7/27/2020 2:45:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1�3 �� 1'� t � 1� 1Z , uur� GA I <br /> HOW TO LOCATE THE POSITION OF THE <br /> 71 SO AT 95% TANK CAPACITY i Measuring Stick <br /> At <br /> The length of the upper tube and the placement of - <br /> the 71 SO valve body determine the shut-off point. <br /> Following the standard instructions for the OPW <br /> 71 SO will provide for initial shutoff at 95% . In all <br /> cases , the upper tube length must be a minimum of <br /> 6 -1 /2" plus the length of the riser pipe. All length jT - <br /> measurements are in inches . Riser Pipe ; <br /> with Face 1 (A) <br /> INSTRUCTIONSSeal Adapto <br /> To Tank 8 <br /> Top (I . D. ) To(Tank <br /> i <br /> 1 . } Find tank capacity ( in gallons ) from tank I' � <br /> calibration chart provided by tank manufacturer, Bottom <br /> I <br /> 2. ) Calculate 95 % of capacity. ell e lel , ell <br /> 6-112" <br /> C? 6 ` Iz ,t 3 . ) Locate the 95% volume number on the tank <br /> calibration chart. <br /> 4 . ) Find the dipstick number (X) which corresponds Figure 1 <br /> to the 95 % tank volume . And , find the dipstick <br /> t10 number (Y) which corresponds to the EXAMPLE <br /> 100%volume . 1 . ) For an Owens-Corning Model G-3 Fiberglass® <br /> Tank Calibration Chart: <br /> L3. 5 5 . ) Subtract the dipstick number (X ) from the tank Tank Capacity - 10 , 000 gal. , nominal 9 ,403 gal . <br /> diameter (Y ) to find the upper tube reference NOTE : Use actual capacity only <br /> number (Z) . <br /> (Y) - (X ) _ (Z} 2 . ) 95% of actual tank capacity = 0.95 x <br /> �f • 5 6 ) Subtract 2" from (Z) to find the upper tube depth 8403 gal . = 8933 gal . <br /> (C )• 3 . ) The closest number which is less than 8933 gal . <br /> (z) W2 = c Is 8910 gal . Choosing the closest number less <br /> than 95% of actual capacity ensures that the <br /> 7 . ) Is C less than 6- 1 /2" ? initial shutoff will occur when the tank is no more <br /> than 95% full . <br /> C :l{ ,S NO Upper tube length is C plus the distance <br /> from the top of the Face Seal Adaptor 4 , ) The calibration chart reading of 8910 gaL <br /> b� installed on the riser pipe to the inside , top corresponds to a dipstick measurement of 82" . <br /> lip of the storage (A) . <br /> 5 • ) Dipstick number (X) = 82" <br /> Upper Tube Length = C + (A) Tank diameter (Y ) = 92" <br /> (Y ) - (X} _ (Z ) (92 "- 82" = 10" ) <br /> YES Upper tube length is 6- 1 /2" plus the riser (Z ) = 10" <br /> pipe measurement (A) . <br /> 7 . ) (Z) - 2" = C { 10" - 2 " = 8 ") <br /> Upper Tube Length = 6- 1 /2" + (A) C = gi <br /> NOTE : You must find the actual tank capacity 7 . ) Is 8" less than 6- 1 /2"? <br /> number that correlates to the 6Al2" + (A) depth <br /> for the station records . This number may also NO Measure the distance from the top of the <br /> be used for the purposes of calibrating an FSA400 Face Seal Adaptor installed on the <br /> electronic tank level system. riser pipe to the inside , top lip of the storage <br /> tank and obtain measurement (A). <br /> n Registered T, M . - Owens Coming Fiberglass Corporation Upper tube length = C + (A) <br /> 64 <br />
The URL can be used to link to this page
Your browser does not support the video tag.