Laserfiche WebLink
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SRH FOOD & GAS 749 E DR MARTIN LUTHER KING JR BLVD May 31 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plans are not current and/or not approved by the EHD. <br /> -The plans for all three tanks left blank"UDC monitoring stops flow of product at the dispenser". <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 5/25/18 and <br /> a test report was submitted on 7/17/18, one month late. A copy of the test report must be submitted within 30 days of <br /> the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a timely <br /> manner. <br /> This is a minor violation. <br /> 115 CCR 2715(a)(1)(B), 2715(a)(3)"Designated Underground Storage Tank Operator Identification Form" not submitted <br /> within 30 days. <br /> Zane Nimmo is performing designated operator inspections at this facility. He is not on the submitted list and <br /> notification was not provided to the EHD within 30 days of the change. Any changes shall be reported to the EHD <br /> within 30 days. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for this facility. <br /> This is a minor violation. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. The plans on site were dated 2014. <br /> Updates were made to the monitoring plans in 2018. A copy of these plans shall be accessible on site at all times. <br /> Immediately locate and retain a current copy on site. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> A designated operator inspection for the following months was performed more than 30 days: <br /> -Conducted 1/20/19, next conducted 2/21/19 (32 days) <br /> The designated operator visual inspections shall be conducted within 30 days or less of the previous inspection. <br /> Ensure that all designated operator inspections are performed within the required time frames. <br /> This is a repeat violation, Class II. <br /> FA0003870 PR0231060 SCO01 05/31/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 Of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />