Laserfiche WebLink
SANJ OA U I Environmental Health Department <br /> COUNTY <br /> — <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SRH FOOD & GAS 749 E DR MARTIN LUTHER KING JR BLVD May 31 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> The 4/17/19 and 5/17/19 designated operator inspection reports were not found on site. Alarm histories were found <br /> for both inspections. Designated operator inspection reports for the previous thirty-six months shall be retained on <br /> site. Locate and ensure that copies of the previous thirty-six months of designated operator monthly inspection <br /> reports are maintained on site. Submit copies of the missing reports to the EHD. <br /> This is a minor violation. <br /> 215 CCR 2712(1) Failure to retain a copy of the permit to operate at the facility. <br /> A copy of the 2019 UST operating permit was not found on site. A copy of the UST operating permit and all <br /> attachments and conditions shall be retained at the facility. Immediately obtain a copy of the permit and retain it on <br /> site. <br /> This is a minor violation. <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. The <br /> underground storage tank system shall be operated to prevent unauthorized releases. Immediately provide approved <br /> secondary containment for the filters under permit and inspection by the EHD. <br /> This is a Class II violation. <br /> 314 HSC 25290.1, 25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the UDC. Secondary <br /> containment shall be provided for all single-walled UST components. Immediately provide approved secondary <br /> containment for the filters under permit and inspection by the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> The monitoring system certification was conducted today and was not witnessed by EHD in its entirety. Looked <br /> inside all sumps and UDCs. Verified sensor locations and piping communication. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by June 30, 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209) 468-3420. <br /> Documents provided: Return to Compliance Certification form, schedule of free CUPA classes <br /> FA0003870 PR0231060 SCO01 05/31/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 Of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />