Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> —COUNTY— <br /> Underground <br /> OUNTY Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENT INC/PACIFIC PRIDE 351 N BECKMAN RD, LODI June 26,2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b)(1-2)Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. Maintenance records for L2-91 <br /> fill fuel alarm on 11/30/18, L8-87 STP fuel alarm on 12/17/18 and L6-Red diesel fuel alarm on 1/11/19 were not <br /> found on site. the monitoring plan for all tanks state yes under record keeping for Tank integrity testing, SIR testing, <br /> Tank gauging , ATG testing, and corrosion protection logs, however these records were not found on site,when the <br /> maintenance supervisor was asked if for the records, he was not able to provide them to the inspector. These <br /> records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6)results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a repeat violation, Class II. <br /> 202 CCR 2715(c)(3), 2715(c)(4)Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> 2018). <br /> "Facility Employee Training Certificate"dated 12/10/19 was found on site stating that employee, Ronnie Ignacio was <br /> trained on 12/10/19. Ronnie Ignacio'date of assuming responsibility is stated as 11/20/19 however the initial training <br /> date was stated to be 12/10/19 both of which dates are in the future, ensure the DO is writing correct dates under <br /> the"Facility Employee Training Certificate".All site employees must be trained prior to taking responsibility as a <br /> facility employee if after October 1, 2018, or within 30 days of hire if prior to October 1, 2018.The"Facility <br /> Employee Training Certificate"shall contain accurate information for all employees trained. Update the"Facility <br /> Employee Training Certificate"to contain the accurate information and submit a copy of the updated form to the <br /> EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class II. <br /> 205 CCR 2712(i), 2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br /> An approved copy of the response plans were not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class II. <br /> FA0003773 PR0231310 SC001 06/26/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />