Laserfiche WebLink
J. Lighting: <br /> 1. CRFC 114252 <br /> In every room and area in which any food is prepared,manufactured,processed,or prepackaged,or in which <br /> equipment or utensils are cleaned, sufficient natural or artificial lighting shall be provided to produce the <br /> following light intensity,while the area is in use: <br /> (a) At least 10-footcandles at a distance of 30 inches above the floor,in walk-in refrigeration units and dryfood <br /> storage areas. <br /> (b) At least 20-foot candles for the following: <br /> (1) At a surface where food is provided for consumer self-service or where fresh produce or prepackaged <br /> foods are sold or offered for consumption. <br /> (2) Inside equipment such as reach-in and under-counter refrigerators. <br /> (3) At a distance of 30 inches above the floor in areas used for handwashing,warewashing,and equipment <br /> and utensil storage, and in toilet rooms. <br /> (c) At least 50-foot candles at a surface where a food employee is working with food or working with utensils or <br /> equipment such as knives, slicers, grinders, or saws where employee safety is a factor and in other areas <br /> and rooms during periods of cleaning. <br /> 2. CRFC 114252.1 <br /> (a) Except as specified in subdivision(b), light bulbs shall be shielded,coated,or otherwise shatter-resistant in <br /> areas where there is non-prepackaged ready-to-eat food, clean equipment, utensils, and linens, or <br /> unwrapped single-use articles. <br /> (b) Shielded, coated, or otherwise shatter-resistant bulbs need not be used in areas used only for storing <br /> prepackaged food in unopened packages,if the integrity of the packages cannot be affected by broken glass <br /> falling onto them and the packages are capable of being cleaned of debris from broken bulbs before the <br /> packages are opened. <br /> (c) Infrared and other heat lamps shall be protected against breakage by a shield surrounding and extending <br /> beyond the bulb so that only the face of the bulb is exposed,or by using approved coated shatter resistant <br /> bulbs. <br /> K. Water: <br /> 1. CRFC 114192 <br /> (a) An adequate,protected,pressurized, potable supply of hot water and cold water shall be provided. Hot water <br /> shall be supplied at a minimum temperature of at least 120°F measured from the faucet, unless otherwise <br /> specified in this part. The water supply shall be from a water system approved by the health officer or the <br /> local enforcement agency. <br /> (b) Any hose used for conveying potable water shall be constructed of nontoxic materials, shall be used for no <br /> other purpose,and shall be clearly labeled as to its use. The hose shall be stored and used so as to be kept <br /> free of contamination. <br /> (c) The potable water supply shall be protected with a backflow or back siphonage protection device when <br /> required by applicable plumbing codes. Exposed piping of a nonpotable water system shall be identified <br /> so that it is readily distinguishable from piping that carries potable water. <br /> 2. CRFC 114195 <br /> (a) The water source and system shall be of sufficient capacity to meet the peak water demands of the food <br /> facility. <br /> (b) Hot water generation and distribution systems shall be sufficient to meet the peak hot water demands <br /> throughout the food facility. <br /> L. Backflow Protection: <br /> CRFC 114192 <br /> (c) The potable water supply shall be protected with a backflow or back siphonage protection device when <br /> required by applicable plumbing codes. Exposed piping of a nonpotable water system shall be identified <br /> so that it is readily distinguishable from piping that carries potable water. <br /> EHD 16-01 10 PLAN CHECK GUIDE <br /> 7/5117 <br />