Laserfiche WebLink
N/AX 2. CRFC 114149.2 <br /> (a) Every hood shall be installed to provide for thorough cleaning of all interior and exterior surfaces, including, <br /> but not limited to,the hood, filters, piping, lights, troughs, hangers,flanges, and exhaust ducts. <br /> (b) Exhaust ventilation hood systems in food preparation and warewashing areas,including components such as <br /> hoods, fans, guards, and ducting, shall be designed to prevent grease or condensation from draining or <br /> dripping onto food, equipment, utensils, linens, and single-use articles. <br /> (c) Filters or other grease extracting equipment shall be designed to be readily removable for cleaning and <br /> replacement if not designed to be cleaned in place. <br /> (d) Every joint and seam shall be substantially tight. No solder shall be used,except for sealing a joint or seam. <br /> (e) When grease gutters are provided they shall drain to a collecting receptacle fabricated, designed, and <br /> installed to be readily accessible for cleaning. <br /> (f) Exhaust hood ducting shall meet the following requirements: <br /> (1) All seams in the duct shall be completely tight to prevent the accumulation of grease. <br /> (2) The ducts shall have sufficient clean-outs to make the ducts readily accessible for cleaning. <br /> (3) All ducts in the exhaust system shall be properly sloped. <br /> (4) Intake and exhaust air ducts shall be cleaned and filters changed so they are not a source of <br /> contamination by dust, dirt, and other materials. <br /> (Hoods are existing to remain) <br /> V. Equipment Requirements: <br /> A. Equipment and Utensils <br /> X 1. CRFC 114130 <br /> (a) Equipment and utensils shall be designed and constructed to be durable and to retain their characteristic <br /> qualities under normal use conditions. <br /> (b) Except as specified in subdivision(c), all new and replacement food-related and utensil-related equipment <br /> shall be certified or classified for sanitation by an American National Standards Institute(ANSI)accredited <br /> certification program. In the absence of an applicable ANSI certified sanitation standard,food-related,and <br /> utensil-related equipment shall be evaluated for approval by the enforcement agency. <br /> (c) Restricted food service facilities need not comply with subdivision (b), depending on the extent of the food <br /> service activities,and if the enforcement officer determines that the equipment meets the characteristics of <br /> subdivision(a). <br /> (d) All new and replacement electrical appliances shall meet applicable Underwriters Laboratories standards for <br /> electrical equipment as determined by an ANSI accredited certification program. <br /> 2. CRFC 114130.1 <br /> Materials that are used in the construction of utensils and food-contact surfaces of equipment shall not allow the <br /> migration of deleterious substances or impart colors,odors,or tastes to food and under normal use conditions <br /> shall be safe, durable, corrosion-resistant, and nonabsorbent, sufficient in weight and thickness to withstand <br /> repeated warewashing, finished to have a smooth, easily cleanable surface, and resistant to pitting, chipping, <br /> crazing, scratching, scoring, distortion, and decomposition. <br /> X 3. CRFC 114130.3 <br /> (a) Multiuse food-contact surfaces shall be all of the following: <br /> (1) Smooth. <br /> (2) Free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections. <br /> (3) Free of sharp internal angles, corners, and crevices. <br /> (4) Finished to have smooth welds and joints. <br /> (5) Except as specified in subdivision (b), accessible for cleaning and inspection by one of the following <br /> methods: <br /> (A) Without being disassembled. <br /> (B) By disassembling without the use of tools. <br /> (C) By easy disassembling with the use of handheld tools commonly available to maintenance and <br /> cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches. <br /> X 4. CRFC 114169 <br /> (a) Equipment that is fixed because it is not easily movable shall be installed so that it is: <br /> (1) Spaced to allow access for cleaning along the sides, behind, and above the equipment. <br /> (2) Spaced from adjoining equipment,walls,and ceilings a distance of not more than one millimeter or one <br /> thirty-second inch. <br /> (3) Sealed to adjoining equipment or walls, if the equipment is exposed to spillage or seepage. <br /> (b) Except as specified in subdivisions(c)and(d),floor-mounted equipment that is not easily movable shall be <br /> sealed to the floor or elevated on legs that provide at least a six-inch clearance between the floor and the <br /> equipment. <br /> EHD 16-01 12 PLAN CHECK GUIDE <br /> 7/5/17 <br />