My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4431
>
1600 - Food Program
>
PR0518138
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 3:43:50 PM
Creation date
7/30/2020 11:33:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0518138
PE
1624
FACILITY_ID
FA0013718
FACILITY_NAME
Wendy's #658 Waterloo RD
STREET_NUMBER
4431
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4431 E WATERLOO Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(c) Notwithstanding subdivision (b), this section shall not apply to display shelving units, display refrigeration <br /> units,and display freezer units located in the consumer shopping areas of a food facility if the floorunderthe <br /> units is maintained clean. <br /> (d) Table-mounted equipment that is not easily movable shall be installed to allow cleaning of the equipment and <br /> areas underneath and around the equipment by being sealed to the table or elevated on legs that provide at <br /> least a four-inch clearance between the table and the equipment. <br /> B. Food Preparation Sink: <br /> N/A 1. CRFC 114163 <br /> (a) Except as specified in subdivision(b), a food preparation sink shall be provided in permanent food facilities <br /> for the washing, rinsing, soaking, thawing, or similar preparation of foods. <br /> (1) The food preparation sink shall have a minimum dimension of 18 inches by 18 inches in length and width <br /> and 12 inches in depth with an integral drainboard or adjacent table at least 18 inches by 18 inches in <br /> length and width. <br /> (2) The food preparation sink shall be located in the food preparation area, provided exclusively for food <br /> preparation, and accessible at all times. <br /> (3) The sink shall be equipped with an adequate supply of hot and cold running water through a mixing <br /> valve. <br /> (b) (1) Food facilities that were approved for operation without a food preparation sink prior to the effective date <br /> of this part need not provide a food preparation sink unless the food facility makes a menu change or <br /> changes their method of operation. <br /> (2) The enforcement officer may approve other methods where the installation of a food preparation sink <br /> would not be readily feasible. <br /> (Food preparation sinks are existing to remain) <br /> C. Hand Washing Sinks: <br /> N/A 1. CRFC 113953 <br /> (a) Handwashing facilities shall be provided within or adjacent to toilet rooms. The number of handwashing <br /> facilities required shall be in accordance with local building and plumbing codes. <br /> (b) (1) Except as otherwise provided in Section 114358,food facilities constructed or extensively remodeled <br /> after January 1, 1996, that handle non-prepackaged food, shall provide facilities exclusively for <br /> handwashing in food preparation areas and in warewashing areas that are not located within or <br /> immediately adjacent to food preparation areas. Handwashing facilities shall be sufficient in number and <br /> conveniently located so as to be accessible at all times for use by food employees. <br /> (2) The handwashing facility shall be separated from the warewashing sink by a metal splashguard with a <br /> height of at least 6 inches that extends from the back edge of the drainboard to the front edge of the <br /> drainboard,the comers of the barrier to be rounded. No splashguard is required if the distance between <br /> the handwashing sink and the warewashing sink drainboards is 24 inches or more. <br /> (c) Handwashing facilities shall be equipped to provide warm water under pressure for a minimum of 15 seconds <br /> through a mixing valve or combination faucet. <br /> (d) An automatic handwashing facility may be installed and used in accordance with the manufacturer's <br /> instructions. <br /> (e) Notwithstanding subdivision(b),the enforcement agency may allow handwashing facilities other than those <br /> required by thip section when it deems that the alternate facilities are adequate. <br /> (Hand washing sinks are existing to remain) <br /> 2 CRFC 113953.2 <br /> A handwashing facility shall be provided with the following in dispensers at,or adjacent to,each handwashing <br /> facility: <br /> (a) Handwashing cleanser. <br /> (b) Sanitary single-use towels or a heated-air hand drying device. <br /> D. Janitorial Facilities: <br /> X 1. CRFC 114279 <br /> (a) At least one curbed cleaning facility orjanitorial sink equipped with a drain shall be provided and conveniently <br /> located for the cleaning of mops or similar wet floor cleaning tools and for the disposal of mop water and <br /> similar liquid waste. <br /> (b) Restricted food service facilities shall be exempt from subdivision (a) if hot water is available for janitorial <br /> purposes and wastewater from janitorial activities is disposed of through an approved sewage disposal <br /> system. <br /> (Janitor sink is existing to remain) <br /> EHD 16-01 13 PLAN CHECK GUIDE <br /> 7/5/17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.