My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4431
>
1600 - Food Program
>
PR0518138
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 3:43:50 PM
Creation date
7/30/2020 11:33:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0518138
PE
1624
FACILITY_ID
FA0013718
FACILITY_NAME
Wendy's #658 Waterloo RD
STREET_NUMBER
4431
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4431 E WATERLOO Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
X 2. CRFC 114279 <br /> A room, area, or cabinet separated from any food preparation or storage area, or warewashing or storage <br /> area shall be provided for the storage of cleaning equipment and supplies. (,Janitor storage is existing to <br /> E. Manual and Machine Warewashing: remain) <br /> X 1. CRFC 114095 <br /> All food facilities in which food is prepared or in which multiservice utensils and equipment are used shall <br /> provide manual methods to effectively clean and sanitize utensils as specified in Section 114099. <br /> (Kitchen equipment is existing to remain) <br /> X 2. CRFC 114099 <br /> (a) Manual warewashing sinks, except as specified in subdivision (c), shall have at least three compartments <br /> with two integral metal drainboards for manually washing, rinsing, and sanitizing equipment and utensils. <br /> (b) Sink compartments shall be large enough to accommodate immersion of the largest equipment and utensils. <br /> If equipment or utensils are not designed to be washed in a warewashing sink,alternate approved methods <br /> as specified in Section 114099.3 shall be followed. <br /> (c) A two-compartment sink that is in use on January 1, 1996, need not be replaced when used as specified in <br /> Section 114099.3. The enforcement officer shall approve the continued use of a two-compartment sink even <br /> upon replacement if the installation of a three-compartment sink would not be readily achievable and where <br /> other approved sanitation methods are used. (Kitchen equipment is existing to remain) <br /> X 3. CRFC 114101 <br /> (a) Mechanical machine warewashing shall be accomplished by using an approved machine installed and <br /> operated in accordance with the manufacturer's specifications. <br /> (b) Soiled items to be cleaned in a warewashing machine shall be loaded in racks, trays, or baskets or onto <br /> conveyors in a position that exposes the items to the unobstructed spray during all cycles and allows the <br /> items to drain. <br /> (c) The velocity,quantity,and distribution of the washwater,type,and concentration of detergent used therein, <br /> and the time the utensils are exposed to the water shall be sufficient to clean the utensils. <br /> (d) Restricted food service facilities need not comply with Section 114130 if the domestic or commercial <br /> dishwasher utilized for warewashing is capable of providing heat to the surface of the utensils of a <br /> temperature of at least 160°F. (Kitchen equipment is existing to remain) <br /> 4. CRFC 114103 <br /> (a) Except as provided in subdivisions(b)and(c),all warewashing equipment shall be provided with two integral <br /> metal drainboards of adequate size and construction. One drainboard shall be attached at the point of entry <br /> for soiled equipment and utensils and one shall be attached at the point of exit for cleaned and sanitized <br /> equipment and utensils. <br /> (b) Where an undercounter warewashing machine is used,there shall be two metal drainboards,one for soiled <br /> equipment and utensils, and one for clean equipment and utensils, located adjacent to the machine. This <br /> requirement may be satisfied by using the drainboards that are part of the manual warewashing sinks if the <br /> facilities are located adjacent to the machine. <br /> (c) Pot and pan washers shall be equipped with drainboards as required in subdivision(a),or shall be equipped <br /> with approved alternative equipment that provides adequate and suitable space for soiled and clean <br /> equipment and utensils. <br /> (d) Drainboards, utensil racks, or tables large enough to accommodate all soiled and cleaned items that may <br /> accumulate during hours of operation shall be provided for necessary utensil holding before cleaning and <br /> after sanitizing. <br /> (e) Sinks and drainboards of warewashing equipment shall be sloped and drained to an approved liquid waste <br /> receptor. <br /> (Kitchen equipment is existing to remain) <br /> EHD 16-01 14 PLAN CHECK GUIDE <br /> 715117 <br />
The URL can be used to link to this page
Your browser does not support the video tag.