COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MICHAEL CANLIS
>
7000
>
2300 - Underground Storage Tank Program
>
PR0232437
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 10:38:59 AM
Creation date
8/3/2020 11:39:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0232437
PE
2361
FACILITY_ID
FA0003787
FACILITY_NAME
SHERIFFS OPERATIONS CTR #1
STREET_NUMBER
7000
Direction
N
STREET_NAME
MICHAEL CANLIS
STREET_TYPE
RD
City
FRENCH CAMP
Zip
95231
APN
19305014
CURRENT_STATUS
01
SITE_LOCATION
7000 N MICHAEL CANLIS RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: I Date: <br /> SHERIFFS OPERATIONS CTR#1 7000 N MICHAEL CANLIS RD, FRENCH CAMP January 25, 2019 <br /> Item#I Remarks <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. The financial responsibility documents <br /> submitted on CERS are dated 1/11/18. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> This is a minor violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the 87 and diesel tanks are not current in CERS. <br /> -The diesel tank form incorrectly states the riser is fiberglass. <br /> -The 87 tank form incorrectly states the vent lines are double-walled. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plans are not current and/or not approved by the EHD. <br /> -The diesel monitoring plan incorrectly states automatic tank gauging is being conducted. <br /> -The diesel monitoring plan incorrectly states the overfill prevention flappers are 6150. The accurate model is <br /> 61 SO. <br /> -The diesel monitoring plan incorrectly states ATG test results are maintained on site and maintenance and <br /> calibration records are not maintained. <br /> -Both monitoring plans incorrectly list the monitoring panel model as a TLS350 or just a 350. The monitoring panel <br /> on site is a TLS-350 Plus. <br /> The monitoring plans must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br /> An accurate UST Monitoring Site Plan was not submitted. Three site maps were uploaded in the most recent CERS <br /> submittal, but none contains complete, accurate information. A site plan must be submitted identifying the locations <br /> where monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the complete UST Monitoring Site Plan. Outdated previously <br /> submitted documents should be discarded from the submittal if they are no longer being used to meet the UST <br /> requirements. <br /> This is a repeat violation, Class II. <br /> 110 CCR 2637(e), 2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test. <br /> Secondary containment testing was performed on August 29, 2018 and a test report was submitted on October 29, <br /> 2018, one month late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary <br /> precautions to ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> FA0003787 PR0232437 SCO01 01/25/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 8 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.